Short-term outcomes of screening mammography using computer-aided detection: a population-based study of medicare enrollees

. 2013 Apr 16;158(8):580-7. doi: 10.7326/0003-4819-158-8-201304160-00002. Short-term outcomes of screening mammography using computer-aided detection: a population-based study of medicare enrollees

Affiliations

Affiliation

Item in Clipboard

Short-term outcomes of screening mammography using computer-aided detection: a population-based study of medicare enrollees

Joshua J Fenton et al. Ann Intern Med. 2013.

. 2013 Apr 16;158(8):580-7. doi: 10.7326/0003-4819-158-8-201304160-00002. Affiliation

Item in Clipboard

Abstract

Background: Computer-aided detection (CAD) has rapidly diffused into screening mammography practice despite limited and conflicting data on its clinical effect.

Objective: To determine associations between CAD use during screening mammography and the incidence of ductal carcinoma in situ (DCIS) and invasive breast cancer, invasive cancer stage, and diagnostic testing.

Design: Retrospective cohort study.

Setting: Medicare program.

Participants: Women aged 67 to 89 years having screening mammography between 2001 and 2006 in U.S. SEER (Surveillance, Epidemiology and End Results) regions (409 459 mammograms from 163 099 women).

Measurements: Incident DCIS and invasive breast cancer within 1 year after mammography, invasive cancer stage, and diagnostic testing within 90 days after screening among women without breast cancer.

Results: From 2001 to 2006, CAD prevalence increased from 3.6% to 60.5%. Use of CAD was associated with greater DCIS incidence (adjusted odds ratio [OR], 1.17 [95% CI, 1.11 to 1.23]) but no difference in invasive breast cancer incidence (adjusted OR, 1.00 [CI, 0.97 to 1.03]). Among women with invasive cancer, CAD was associated with greater likelihood of stage I to II versus III to IV cancer (adjusted OR, 1.27 [CI, 1.14 to 1.41]). In women without breast cancer, CAD was associated with increased odds of diagnostic mammography (adjusted OR, 1.28 [CI, 1.27 to 1.29]), breast ultrasonography (adjusted OR, 1.07 [CI, 1.06 to 1.09]), and breast biopsy (adjusted OR, 1.10 [CI, 1.08 to 1.12]).

Limitation: Short follow-up for cancer stage, potential unmeasured confounding, and uncertain generalizability to younger women.

Conclusion: Use of CAD during screening mammography among Medicare enrollees is associated with increased DCIS incidence, the diagnosis of invasive breast cancer at earlier stages, and increased diagnostic testing among women without breast cancer.

Primary funding source: Center for Healthcare Policy and Research, University of California, Davis.

PubMed Disclaimer

Conflict of interest statement

Potential Conflicts of Interest: Disclosures can be viewed at www.acponline.org/authors/icmje/ConflictOfInterestForms.do?msNum=M12-2025 .

Similar articles Cited by References
    1. Fenton JJ, Foote SB, Green P, Baldwin LM. Diffusion of computer-aided mammography after mandated Medicare coverage. Arch Intern Med. 2010;170:987–989. [PMID: 20548013] - PubMed
    1. Rao VM, Levin DC, Parker L, Cavanaugh B, Frangos AJ, Sunshine JH. How widely is computer-aided detection used in screening and diagnostic mammography? J Am Coll Radiol. 2010;7:802–805. [PMID: 20889111] - PubMed
    1. Gross CP, Long JB, Ross JS, Abu-Khalaf MM, Wang R, Killelea BK, et al. The cost of breast cancer screening in the Medicare population. JAMA Intern Med. 2013;173:220–226. [PMID: 23303200] - PMC - PubMed
    1. Bazzocchi M, Mazzarella F, Del Frate C, Girometti R, Zuiani C. CAD systems for mammography: a real opportunity? A review of the literature. Radiol Med. 2007;112:329–353. [PMID: 17440698] - PubMed
    1. Cupples TE, Cunningham JE, Reynolds JC. Impact of computer-aided detection in a regional screening mammography program. AJR Am J Roentgenol. 2005;185:944–950. [PMID: 16177413] - PubMed

RetroSearch is an open source project built by @garambo | Open a GitHub Issue

Search and Browse the WWW like it's 1997 | Search results from DuckDuckGo

HTML: 3.2 | Encoding: UTF-8 | Version: 0.7.3