A RetroSearch Logo

Home - News ( United States | United Kingdom | Italy | Germany ) - Football scores

Search Query:

Showing content from https://link.springer.com/article/10.1007/s10439-020-02699-3 below:

Comparison of in Vascular Bioreactors and In Vivo Models of Degradation and Cellular Response of Mg–Zn–Mn Stents

References
  1. Aneja, R., C. Yates, S. Josson, L. Chung, and H. Joshi. EM044, a novel noscapinoid induces apoptosis in prostate cancer cells while sparing the normal stroma. Mol. Cancer Ther. 6:32–34, 2007.

    Article  Google Scholar 

  2. Bjork, J. W., and R. T. Tranquillo. Transmural flow bioreactor for vascular tissue engineering. Biotechnol. Bioeng. 104:1197–1206, 2009.

    Article  CAS  Google Scholar 

  3. Doepke, A., J. Kuhlmann, X. Guo, R. T. Voorhees, and W. R. Heineman. A system for characterizing Mg corrosion in aqueous solutions using electrochemical sensors and impedance spectroscopy. Acta Biomater. 9:9211–9219, 2013.

    Article  CAS  Google Scholar 

  4. Echeverry-Rendon, M., J. P. Allain, S. M. Robledo, F. Echeverria, and M. C. Harmsen. Coatings for biodegradable magnesium-based supports for therapy of vascular disease: a general view. Mater. Sci. Eng. C. 102:150–163, 2019.

    Article  CAS  Google Scholar 

  5. Ellis, S. G., D. J. Kereiakes, D. C. Metzger, R. P. Caputo, D. G. Rizik, P. S. Teirstein, M. R. Litt, A. Kini, A. Kabour, S. O. Marx, J. J. Popma, R. M. Greevy, Z. Zhang, C. Simonton, and G. W. Stone. Everolimus-eluting bioresorbable scaffolds for coronary artery disease. N. Engl. J. Med. 373:1905–1915, 2015.

    Article  CAS  Google Scholar 

  6. Erbel, R., C. D. Mario, J. Bartunek, J. Bonnier, B. De Bruyne, F. R. Eberli, P. Erne, M. Haude, B. Heublein, M. Horrigan, C. Ilsley, D. Böse, J. Koolen, T. F. Lüscher, N. Weissman, and R. Waksman. Temporary scaffolding of coronary arteries with bioabsorbable magnesium stents: a prospective, non-randomised multicentre trial. Lancet. 369:1869–1875, 2007.

    Article  CAS  Google Scholar 

  7. Gu, X., Y. Zheng, Y. Cheng, S. Zhong, and T. Xi. In vitro corrosion and biocompatibility of binary magnesium alloys. Biomaterials. 30:484–498, 2009.

    Article  CAS  Google Scholar 

  8. Haude, M., R. Erbel, P. Erne, S. Verheye, P. Vermeersch, H. Degen, D. Bose, R. Waksman, N. Weissman, F. Prati, and J. Koolen. Three year clinical and imaging data of the paclitaxel-eluting absorbable magnesium scaffold (Dreams) from the Biosolve-I study. Circulation. 130:A11993–A11993, 2014.

    Google Scholar 

  9. Haude, M., H. Ince, A. Abizaid, R. Toelg, P. A. Lemos, C. Von Birgelen, E. H. Christiansen, W. Wijns, F. J. Neumann, C. Kaiser, E. Eeckhout, S. T. Lim, J. Escaned, H. M. Garcia-Garcia, and R. Waksman. Safety and performance of the second-generation drug-eluting absorbable metal scaffold in patients with de-novo coronary artery lesions (BIOSOLVE-II): 6 month results of a prospective, multicentre, non-randomised, first-in-man trial. Lancet. 387:31–39, 2016.

    Article  CAS  Google Scholar 

  10. Haude, M., H. Ince, S. Kische, A. Abizaid, R. Tölg, P. A. Lemos, N. M. Van Mieghem, S. Verheye, C. Von Birgelen, E. H. Christiansen, W. Wijns, H. M. Garcia-Garcia, and V. Waksman. Sustained safety and clinical performance of a drug-eluting absorbable metal scaffold up to 24 months: pooled outcomes of BIOSOLVE-II and BIOSOLVE-III. Eurointervention. 13:432–439, 2017.

    Article  Google Scholar 

  11. Huang, A. H., and L. E. Niklason. Engineering biological-based vascular grafts using a pulsatile bioreactor. JOVE. 52:1–7, 2011.

    Google Scholar 

  12. Iqbal, J., Y. Onuma, J. Ormiston, A. Abizaid, R. Waksman, and P. Serruys. Bioresorbable scaffolds: rationale, current status, challenges, and future. Eur. Heart J. 35:765–776, 2013.

    Article  Google Scholar 

  13. Jinnouchi, H., S. Torii, A. Sakamoto, F. D. Kolodgie, R. Virmani, and A. V. Finn. Fully bioresorbable vascular scaffolds: lessons learned and future directions. Nat. Rev. Cardiol. 16:286–304, 2019.

    Article  CAS  Google Scholar 

  14. Kereiakes, D. J., S. G. Ellis, C. Metzger, R. P. Caputo, D. G. Rizik, P. S. Teirstein, M. R. Litt, A. Kini, A. Kabour, S. O. Marx, J. J. Popma, R. M. Greevy, Z. Zhang, C. Simonton, and G. W. Stone. 3-year clinical outcomes with everolimus-eluting bioresorbable coronary scaffolds. J. Am. Coll. Cardiol. 70:2852–2862, 2017.

    Article  CAS  Google Scholar 

  15. King, A. D., N. Birbilis, and J. R. Scully. Accurate electrochemical measurement of magnesium corrosion rates; a combined impedance, mass-loss and hydrogen collection study. Electrochim. Acta. 121:394–406, 2014.

    Article  CAS  Google Scholar 

  16. Laukart, J. Fluid-flow handling in bioprocess operations. Genet. Eng. News. 23:1–50, 2003.

    Google Scholar 

  17. Loos, A., R. Rohde, A. Haverich, and S. Barlach. In vitro and in vivo biocompatibility testing of absorbable metal stents. Macromol. Symp. 253:103–108, 2007.

    Article  CAS  Google Scholar 

  18. Ma, J., N. Zhao, L. Betts, and D. H. Zhu. Bio-adaption between magnesium alloy stent and the blood vessel: a review. J. Mater. Sci. Technol. 32:815–826, 2016.

    Article  CAS  Google Scholar 

  19. Marco, I., F. Feyerabend, R. Willumeit-Roemer, and O. Van der Biest. Degradation testing of Mg alloys in Dulbecco’s modified eagle medium: influence of medium sterilization. Mater. Sci. Eng. C. 62:68–78, 2016.

    Article  CAS  Google Scholar 

  20. Mochizuki, A., C. Yahata, and H. Takai. Cytocompatibility of magnesium and AZ31 alloy with three types of cell lines using a direct in vitro method. J. Mater. Sci. Mater. M. 27:145.1–145.10, 2016.

    Article  Google Scholar 

  21. Sivarapatna, A., M. Ghaedi, A. V. Le, J. J. Mendez, Y. Qyang, and L. E. Niklason. Arterial specification of endothelial cells derived from human induced pluripotent stem cells in a biomimetic flow bioreactor. Biomaterials. 53:621–633, 2015.

    Article  CAS  Google Scholar 

  22. Waksman, R., R. Pakala, P. K. Kuchulakanti, R. Baffour, D. Hellinga, R. Seabron, F. O. Tio, E. Wittchow, S. Hartwig, C. Harder, R. Rohde, B. Heublein, A. Andreae, K. H. Waldmann, and A. Haverich. Safety and efficacy of bioabsorbable magnesium alloy stents in porcine coronary arteries. Catheter. Cardio. Inte. 68:607–617, 2006.

    Article  Google Scholar 

  23. Wang, J., Y. Jang, G. Wan, V. Giridharan, G. L. Song, Z. Xu, Y. Koo, P. Qi, J. Sankar, N. Huang, and Y. Yun. Flow-induced corrosion of absorbable magnesium alloy: in-situ and real-time electrochemical study. Corros. Sci. 104:277–289, 2016.

    Article  CAS  Google Scholar 

  24. Wang, J., C. E. Smith, J. Sankar, Y. Yun, and N. Huang. Absorbable magnesium-based stent: physiological factors to consider for in vitro degradation assessments. Regen. Biomater. 2:59–69, 2015.

    Article  CAS  Google Scholar 

  25. Wang, J., L. Liu, Y. Wu, M. F. Maitz, Z. Wang, Y. Koo, A. Zhao, J. Sankar, D. Kong, N. Huang, and Y. Yun. Ex vivo blood vessel bioreactor for analysis of the biodegradation of magnesium stent models with and without vessel wall integration. Acta Biomater. 50:546–555, 2017.

    Article  CAS  Google Scholar 

  26. Wang, J., V. Giridharan, V. Shanov, Z. Xu, B. Collins, L. White, Y. Jang, J. Sankar, N. Huang, and Y. Yun. Flow-induced corrosion behavior of absorbable magnesium-based stents. Acta Biomater. 10:5213–5223, 2014.

    Article  CAS  Google Scholar 

  27. Yang, L., N. Hort, R. Willumeit, and F. Feyerabend. Effects of corrosion environment and proteins on magnesium corrosion. Corros. Eng. Sci. Techn. 47:335–339, 2012.

    Article  CAS  Google Scholar 

  28. Ye, C., J. Wang, A. Zhao, D. He, M. F. Maitz, N. Zhou, and N. Huang. Atorvastatin eluting coating for magnesium-based stents: control of degradation and endothelialization in a microfluidic assay and in vivo. Adv. Mater. Technol. 5:1–11, 2020.

    Google Scholar 

  29. Zhang, H., W. Deng, X. Wang, S. Wang, J. Ge, and E. Toft. Solely abluminal drug release from coronary stents could possibly improve reendothelialization. Catheter. Cardio. Inte. 88:E59–E66, 2016.

    Article  Google Scholar 

  30. Zhang, J., H. Li, W. Wang, H. Huang, J. Pei, H. Qu, G. Yuan, and Y. Li. The degradation and transport mechanism of a Mg-Nd-Zn-Zr stent in rabbit common carotid artery: a 20-month study. Acta Biomater. 69:372–384, 2018.

    Article  CAS  Google Scholar 

  31. Zhao, N., and D. Zhu. Endothelial responses of magnesium and other alloying elements in magnesium-based stent materials. Metallomics. 7:118–128, 2014.

    Article  Google Scholar 

Download references


RetroSearch is an open source project built by @garambo | Open a GitHub Issue

Search and Browse the WWW like it's 1997 | Search results from DuckDuckGo

HTML: 3.2 | Encoding: UTF-8 | Version: 0.7.4