Ashton, J. H., J. P. Vande Geest, B. R. Simon, and D. G. Haskett. Compressive mechanical properties of the intraluminal thrombus in abdominal aortic aneurysms and fibrin-based thrombus mimics. J. Biomech. 42:197–201, 2009.
Bird, R. B., and B. D. Marsh. Viscoelastic hysteresis. Part I. Model predictions. Trans. Soc. Rheol. 12:479–488, 1968.
Chueh, J. Y., A. K. Wakhloo, G. H. Hendricks, C. F. Silva, J. P. Weaver, and M. J. Gounis. Mechanical characterization of thromboemboli in acute ischemic stroke and laboratory embolus analogs. AJNR. Am. J. Neuroradiol. 32:1237–1244, 2011.
Cines, D. B., T. Lebedeva, C. Nagaswami, V. Hayes, W. Massefski, R. I. Litvinov, L. Rauova, T. J. Lowery, and J. W. Weisel. Clot contraction: compression of erythrocytes into tightly packed polyhedra and redistribution of platelets and fibrin. Blood 123:1596–1603, 2014.
Di Martino, E., S. Mantero, F. Inzoli, G. Melissano, D. Astore, R. Chiesa, and R. Fumero. Biomechanics of abdominal aortic aneurysm in the presence of endoluminal thrombus: experimental characterisation and structural static computational analysis. Eur. J. Vasc. Endovasc. Surg. 15:290–299, 1998.
Duffy, S., M. Farrell, K. McArdle, J. Thornton, D. Vale, E. Rainsford, L. Morris, D. S. Liebeskind, E. Maccarthy, and M. Gilvarry. Novel methodology to replicate clot analogs with diverse composition in acute ischemic stroke. J. Neurointerv. Surg. 9:486–491, 2016.
Ferry, J. D., and P. R. Morrison. Chemical, clinical, and immunological studies on the prodcuts of human plasma fractionation. XVI. Fibrin clots, fibrin films, and fibrinogen plastics. J. Clin. Invest. 23:566–572, 1944.
Gasser, T. C., G. Görgülü, M. Folkesson, and J. Swedenborg. Failure properties of intraluminal thrombus in abdominal aortic aneurysm under static and pulsating mechanical loads. J. Vasc. Surg. 48:179–188, 2008.
Goyal, M., et al. Randomized assessment of rapid endovascular treatment of ischemic stroke. N. Engl. J. Med. 372:1019–1030, 2015.
Gunning, G. M., K. Mcardle, M. Mirza, S. Duffy, M. Gilvarry, and P. A. Brouwer. Clot friction variation with fibrin content; implications for resistance to thrombectomy. J. Neurointerventioal Surg. 372:1019–1030, 2016.
Hinnen, J. W., D. J. Rixen, O. H. J. Koning, J. H. van Bockel, and J. F. Hamming. Development of fibrinous thrombus analogue for in-vitro abdominal aortic aneurysm studies. J. Biomech. 40:289–295, 2007.
Huang, C.-C., P.-Y. Chen, and C.-C. Shih. Estimating the viscoelastic modulus of a thrombus using an ultrasonic shear-wave approach. Med. Phys. 40:42901, 2013.
Johnson, S., J. Chueh, M. J. Gounis, R. McCarthy, J. P. McGarry, P. E. McHugh, and M. Gilvarry. Mechanical behavior of in vitro blood clots and the implications for acute ischemic stroke treatment. J. Neurointerv. Surg. 2019. https://doi.org/10.1136/neurintsurg-2019-015489.
Kim, O. V., R. I. Litvinov, M. S. Alber, and J. W. Weisel. Quantitative structural mechanobiology of platelet-driven blood clot contraction. Nat. Commun. 8:1274, 2017.
Kim, J., and M. A. Srinivasan. Characterization of Viscoelastic Soft Tissue Properties from In Vivo Animal Experiments and Inverse Fe Parameter Estimation. Berlin: Springer, pp. 599–606, 2005.
Krasokha, N., W. Theisen, S. Reese, P. Mordasini, C. Brekenfeld, J. Gralla, J. Slotboom, G. Schrott, and H. Monstadt. Mechanical properties of blood clots—a new test method. Materwiss. Werksttech. 41:1019–1024, 2010.
Krueger, K., P. Deissler, S. Coburger, J. W. U. Fries, and K. Lackner. How thrombus model impacts the in vitro study of interventional thrombectomy procedures. Invest. Radiol. 39:641–648, 2004.
Liebeskind, D. S., N. Sanossian, W. H. Yong, S. Starkman, M. P. Tsang, A. L. Moya, D. D. Zheng, A. M. Abolian, D. Kim, L. K. Ali, S. H. Shah, A. Towfighi, B. Ovbiagele, C. S. Kidwell, S. Tateshima, R. Jahan, G. R. Duckwiler, F. Vinuela, N. Salamon, J. P. Villablanca, H. V. Vinters, V. J. Marder, and J. L. Saver. CT and MRI early vessel signs reflect clot composition in acute stroke. Stroke 42:1237–1243, 2011.
Liebig, T., J. Reinartz, R. Hannes, E. Miloslavski, and H. Henkes. Comparative in vitro study of five mechanical embolectomy systems: effectiveness of clot removal and risk of distal embolization. Neuroradiology 50:43–52, 2008.
Malone, F., E. McCarthy, P. Delassus, P. Fahy, J. Kennedy, A. J. Fagan, and L. Morris. The mechanical characterisation of bovine embolus analogues under various loading conditions. Cardiovasc. Eng. Technol. 9:489–502, 2018.
Marder, V. J., W. C. Aird, J. S. Bennett, S. Schulman, and G. C. White. Hemostasis and Thrombosis: Basic Principles and Clinical Practice, Vol. 2. Philadelphia: Lippincott Williams & Wilkins, 2012.
Nolan, D. R., and J. P. McGarry. On the correct interpretation of measured force and calculation of material stress in biaxial tests. J. Mech. Behav. Biomed. Mater. 53:187–199, 2016.
Nolan, D. R., and J. P. McGarry. On the compressibility of arterial tissue. Ann. Biomed. Eng. 44:993–1007, 2016.
Riha, P., X. Wang, R. Liao, and J. Stoltz. Elasticity and fracture strain of whole blood clots. Clin. Hemorheol. Microcirc. 21:45–49, 1999.
Saldívar, E., J. N. Orje, and Z. M. Ruggeri. Tensile destruction test as an estimation of partial proteolysis in fibrin clots. Am. J. Hematol. 71:119–127, 2002.
Schmitt, C., A. Hadj Henni, and G. Cloutier. Characterization of blood clot viscoelasticity by dynamic ultrasound elastography and modeling of the rheological behavior. J. Biomech. 44:622–629, 2011.
Siller-Matula, J. M., R. Plasenzotti, A. Spiel, P. Quehenberger, and B. Jilma. Interspecies differences in coagulation profile. Thromb. Haemost. 100:397–404, 2008.
Slaboch, C. L., M. S. Alber, E. D. Rosen, and T. C. Ovaert. Mechano-rheological properties of the murine thrombus determined via nanoindentation and finite element modeling. J. Mech. Behav. Biomed. Mater. 10:75–86, 2012.
Teng, Z., J. Feng, Y. Zhang, Y. Huang, M. P. F. Sutcliffe, A. J. Brown, Z. Jing, J. H. Gillard, and Q. Lu. Layer- and direction-specific material properties, extreme extensibility and ultimate material strength of human abdominal aorta and aneurysm: a uniaxial extension study. Ann. Biomed. Eng. 43:2745–2759, 2015.
Tutwiler, V., A. R. Mukhitov, A. D. Peshkova, G. Le Minh, R. R. Khismatullin, J. Vicksman, C. Nagaswami, R. I. Litvinov, and J. W. Weisel. Shape changes of erythrocytes during blood clot contraction and the structure of polyhedrocytes. Sci. Rep. 8:17907, 2018.
Tutwiler, V., A. D. Peshkova, I. A. Andrianova, D. R. Khasanova, J. W. Weisel, and R. I. Litvinov. Contraction of blood clots is impaired in acute ischemic stroke. Arterioscler. Thromb. Vasc. Biol. 37:271–279, 2017.
van Dam, E. A., S. D. Dams, G. W. M. Peters, M. C. M. Rutten, G. W. H. Schurink, J. Buth, and F. N. van de Vosse. Determination of linear viscoelastic behavior of abdominal aortic aneurysm thrombus. Biorheology 43:695–707, 2006.
van Dam, E. A., S. D. Dams, G. W. M. Peters, M. C. M. Rutten, G. W. H. Schurink, J. Buth, and F. N. van de Vosse. Non-linear viscoelastic behavior of abdominal aortic aneurysm thrombus. Biomech. Model Mechanobiol. 7:127–137, 2008.
Van Der Worp, H. B., and J. Van Gijn. Acute ischemic stroke. N. Engl. J. Med. 357:572–579, 2007.
van Kempen, T. H. S., G. W. M. Peters, and F. N. van de Vosse. A constitutive model for the time-dependent, nonlinear stress response of fibrin networks. Biomech. Model. Mechanobiol. 14:995–1006, 2015.
Vande Geest, J. P., M. S. Sacks, D. A. Vorp, D. A. Vorp, B. Ray, G. Kuhan, I. C. Chetter, and P. T. McCollum. A planar biaxial constitutive relation for the luminal layer of intra-luminal thrombus in abdominal aortic aneurysms. J. Biomech. 39:2347–2354, 2006.
Wang, D. H., M. Makaroun, M. W. Webster, and D. A. Vorp. Mechanical properties and microstructure of intraluminal thrombus from abdominal aortic aneurysm. J. Biomech. Eng. 123:536–539, 2001.
Wang, X., J. A. Schoen, and M. E. Rentschler. A quantitative comparison of soft tissue compressive viscoelastic model accuracy. J. Mech. Behav. Biomed. Mater. 20:126–136, 2013.
Weafer, F. M., S. Duffy, I. Machado, G. Gunning, P. Mordasini, E. Roche, P. E. McHugh, and M. Gilvarry. Characterization of strut indentation during mechanical thrombectomy in acute ischemic stroke clot analogs. J. Neurointerv. Surg. 2019. https://doi.org/10.1136/neurintsurg-2018-014601.
Xie, H., K. Kim, S. R. Aglyamov, S. Y. Emelianov, M. O’Donnell, W. F. Weitzel, S. K. Wrobleski, D. D. Myers, T. W. Wakefield, and J. M. Rubin. Correspondence of ultrasound elasticity imaging to direct mechanical measurement in aging DVT in rats. Ultrasound Med. Biol. 31:1351–1359, 2005.
RetroSearch is an open source project built by @garambo | Open a GitHub Issue
Search and Browse the WWW like it's 1997 | Search results from DuckDuckGo
HTML:
3.2
| Encoding:
UTF-8
| Version:
0.7.4