Balossino, R., F. Gervaso, F. Migliavacca, and G. Dubini. Effects of different stent designs on local hemodynamics in stented arteries. J. Biomech. 41(5):1053–1061, 2008.
Bathe, K. J. Theory and Modeling Guide, Vol. I, II. Watertown: ADINA and ADINA-F, 2006.
Calay, R. K., J. Kurujareon, and A. E. Holdo. Numerical simulation of respiratory flow patterns within human lungs. Respir. Physiol. Neurobiol. 130:201–221, 2002.
Charokopos, N., C. N. Foroulis, E. Rouska, M. N. Sileli, N. Papadopoulos, and C. Papakonstantinou. The management of post-intubation tracheal stenoses with self-expandable stents: early and long-term results in 11 cases. Eur. J. Cardiothorac. Surg. 40(4):919–924, 2011.
Chiastra, C., S. Morlacchi, S. Pereira, G. Dubini, and F. Migliavacca. Computational fluid dynamics of stented coronary bifurcations studied with a hybrid discretization method. Eur. J. Mech. B/Fluids 35:76–84, 2012.
Chung, F. T., H. C. Chen, C. L. Chou, C. T. Yu, C. H. Kuo, and H. P. Kuo. An outcome analysis of self-expandable metallic stents in central airway obstruction: a cohort study. J. Cardiothorac. Surg. 8(6):46, 2011.
Dasgupta, A., B. L. Dolmatch, and W. J. A.-S. P. N. M. A. C. Mehta. Self-expandable metallic airway stent insertion employing flexible bronchoscopy: preliminary results. Chest 114(1):106–109, 1998.
De Gregorio, M. A. Prótesis traqueobronquiales en radiología intervencionista, Técnicas intervencionistas en el tórax (1st ed.). Zaragoza: Aqua, p. 343, 2003.
Dumon, F. A dedicated tracheobronchial stent. Chest 97:328–332, 1990.
Dutau, H. Airway stenting for benign tracheal stenosis: what is really behind the choice of the stent? Eur. J. Cardiothorac. Surg. 40(4):924–925, 2011.
Fernandez Bussy, S., O. Akindipe, V. Kulkarni, W. Swafford, M. Baz, and M. A. Jantz. Clinical experience with a new removable tracheobronchial stent in the management of airway complications after lung transplantation. J. Heart Lung Transplant 28(7):683–688, 2009.
Food and Drug Administration. FDA public health notification: complications from metallic tracheal stents in patients with benign airway disorders, URL: http://www.fda.gov/MedicalDevices/Safety/AlertsandNotices/PublicHealthNotifications/ucm062115.htm
Fruchter, O., Y. Raviv, and B. D. F. Kramer. Removal of metallic tracheobronchial stents in lung transplantation with flexible bronchoscopy. J. Cardiothorac. Surg. 12(5):72, 2010.
Gaafar, A. H., A. Y. Shaaban, and M. S. Elhadidi. The use of metallic expandable tracheal stents in the management of inoperable malignant tracheal obstruction. Eur. Arch. Otorhinolaryngol. 269(1):247–253, 2012.
García, A., E. Peña, and M. A. Martínez. Influence of geometrical parameters on radial force during self-expanding stent deployment. Application for a variable radial stiffness stent. J. Mech. Behav. Biomed. Mater. 10:166–175, 2012.
Gogas, B. D., C. V. Bourantas, H. M. Garcia-Garcia, Y. Onuma, T. Muramatsu, V. Farooq, R. Diletti, R. J. M. van Geuns, B. de Bruyne, B. Chevalier, L. Thuesen, P. C. Smits, D. Dudek, J. Koolen, S. Windecker, R. Whitbourn, D. McClean, C. Dorange, K. Miquel-Hébert, S. Veldhof, R. Rapoza, J. A. Ormiston, and P. W. J. C. Serruys. The edge vascular response following implantation of the absorb everolimus-eluting bioresorbable vascular scaffold and the XIENCE V metallic everolimus-eluting stent. first serial follow-up assessment at six months and two years: insights from the first-in-man ABSORB Cohort B and SPIRIT II trials. EuroIntervention 9(6):709–720, 2013.
Guo, J., G. Teng, G. Zhu, S. He, G. Deng, and J. He. Self-expandable stent loaded with 125i seeds: Feasibility and safety in a rabbit model. Eur. J. Radiol. 61(2):356–361, 2007.
Gurm, H. S., T. Boyden, and K. B. Welch. Comparative safety and efficacy of a sirolimus-eluting versus paclitaxel-eluting stent: a meta-analysis. Am. Heart J. 155(4):630–639, 2008.
Hautmann, H., M. Bauer, K. J. Pfeifer, and R. M. Huber. Flexible bronchoscopy: a safe method for metal stent implantation in bronchial disease. Ann. Thorac. Surg. 69(2):398–401, 2000.
Husain, S. A., D. Finch, M. Ahmed, A. Morgan, and M. R. Hetzel. Long-term follow-up of ultraflex metallic stents in benign and malignant central airway obstruction. Ann. Thorac. Surg. 83(4):1251–1256, 2007.
Joffre, F., H. Rousseau, Z. Qian, and R. Chemali. Vascular stent-stent techniques: Part 2. Self-expandable intravascular stent: long-term results, Interventional Radiology. Philadelphia: Williams & Wilkins, 1997.
Jones, M. C., F. A. Rueggeberg, H. A. Faircloth, A. J. Cunningham, C. M. Bush, J. D. Prosser, J. L. Waller, N. G. Postma, and P. M. Weinberger. Defining the biomechanical properties of the rabbit trachea. Laryngoscope 124(10):2352–2358, 2014.
Kamaruzaman, N. A., E. Kardia, N. Á. Kamaldin, A. Z. Latahir, and B. H. Yahaya. The rabbit as a model for studying lung disease and stem cell therapy. BioMed Res. Int. 2013:1–12, 2013.
Keller, B. K., C. M. Amatruda, D. R. Hose, J. Gunn, P. V. Lawford, G. Dubini, F. Migliavacca, and A. J. Narracott. Contribution of mechanical and fluid stresses to the magnitude of in-stent restenosis at the level of individual stent struts. Cardiovasc. Eng. Technol. 5(2):164–175, 2014.
Kim, J. H., H. Y. Song, J. H. Park, B. D. Ye, Y. S. Yoon, and J. C. Kim. Metallic stent placement in the palliative treatment of malignant colonic obstructions: primary colonic versus extracolonic malignancies. J. Vasc. Interv. Radiol. 22(12):1727–1732, 2011.
Kleinstreuer, C., Z. Li, C. Basciano, S. Seelecke, and M. Farber. Computational mechanics of nitinol stent grafts. J. Biomech. 41:2370–2378, 2008.
Makris, D., and C. H. Marquette. Tracheobronchial stenting and central airway replacement. Curr. Opin. Pulm. Med. 13(4):278–283, 2007.
Malvè, M., I. Barreras, J. L. López-Villalobos, A. Ginel, and M. Doblaré. Computational fluid-dynamics optimization of a human tracheal endoprosthesis. Int. Commun. Heat Mass Transfer 39:575–581, 2012.
Malvè, M., A. Pérez del Palomar, S. Chandra, J. L. López-Villalobos, E. Finol, A. Ginel, and M. Doblaré. FSI analysis of a human trachea before and after prosthesis implantation. J. Biomech. Eng. 133:071003–071012, 2011.
Malvè, M., A. Pérez del Palomar, J. L. López-Villalobos, A. Ginel, and M. Doblaré. FSI analysis of the coughing mechanism in a human trachea. Ann. Biomed. Eng. 38(4):1556–1565, 2010.
Malvè, M., A. Pérez del Palomar, A. Mena, O. Trabelsi, J. L. López-Villalobos, A. Ginel, F. Panadero, and M. Doblaré. Numerical modeling of a human stented trachea under different stent designs. Int. Commun. Heat Mass Transfer 38(7):855–862, 2011.
Malvè, M., A. Pérez del Palomar, O. Trabelsi, J. L. López-Villalobos, A. Ginel, and M. Doblaré. Modeling of the fluid-structure interaction of a human trachea under different ventilation conditions. Int. Commun. Heat Mass Transfer 38:10–15, 2010.
Malvè, M., C. Serrano, R. Fernández-Parra, E. Peña, F. Lostalé, M. A. D. Gregorio, and M. A. Martínez. Modeling the air mass transfer through a healthy and a stented rabbit trachea: CT-images, computer simulations and experimental study. Int. Commun. Heat Mass Transfer 53:1–8, 2014.
Morlacchi, S., B. Keller, P. Arcangeli, M. Balzan, F. Migliavacca, G. Dubini, J. Gunn, N. Arnold, A. Narracott, D. Evans, and P. Lawford. Hemodynamics and in-stent restenosis: micro-ct images, histology, and computer simulations. Ann. Biomed. Eng. 39(10):2615–2626, 2011.
Mroz, R. M., K. Kordecki, M. D. Kozlowski, M. D. Baniukiewicz, A. Lewszuk, and Z. Bondyra. Severe respiratory distress caused by central airway obstruction treated with self-expandable metallic stents. J. Physiol. Pharmacol. 59(Suppl 6):491–497, 2008.
Novotny, L., M. Crha, P. Rauser, A. Hep, J. M. A. Necas, and D. Vondrys. Novel biodegradable polydioxanone stents in a rabbit airway model. J. Thoracic Cardiovasc. Surg. 143(2):437–444, 2012.
Qian, J. Y., F. Zhang, B. Fan, L. Ge, Q. B. Wang, and J. B. Ge. A more than 2 year follow-up of incomplete apposition after drug-eluting stent implantation. Chin. Med. J. (English Edition) 121(6):498–502, 2008.
Rafanan, A. L., and A. C. Mehta. Stenting of the tracheobronchial tree. Radiol. Clin. North Am. 38(2):395–408, 2000.
Rauber, K., C. Franke, and W. S. Rau. Self-expanding stainless steel endotracheal stents: an animal study. Cardiovasc. Interv. Radiol. 12(5):274–276, 1989.
Ruegemer, J. L., J. A. Perkins, K. S. Azarow, L. K. O’Bryant, R. E. Nielsen, and R. W. Thomas. Effect of the Palmaz balloon-expandable metallic stent in the trachea of pigs. Otolaryngol. Head Neck Surg. 121(1):92–97, 1999.
Saad, C. P., S. Murthy, G. Krizmanich, and A. C. Mehta. Self-expandable metallic airway stents and flexible bronchoscopy: long-term outcomes analysis. Chest 124(5):1993–1999, 2003.
Saito, Y., and H. Imamura. Airway stenting. Surg. Today 35(4):265–270, 2005.
Sawada, S., Y. Tanabe, Y. Fujiwara, T. Koyama, N. Tanigawa, M. Kobayashi, Y. Katsube, and H. Nakamura. Endotracheal expandable metallic stent placement in dogs. Acta Radiol. 32(1):79–80, 1991.
Seijo, L. M., and J. Ancochea. In search of the ideal tracheobronchial stent: metal or silicone? Archivos de Bronconeumología 40(7):293–294, 2004.
Stettler, C., S. Wandel, S. Allemann, A. Kastrati, M. C. Morice, A. Schoemig, M. E. Pfisterer, G. W. Stone, M. B. Leon, J. S. de Lezo, J. J. Goy, S. J. Park, M. Sabaté, M. J. Suttorp, H. Kelbaek, C. Spaulding, M. Menichelli, P. Vermeersch, M. T. Dirksen, P. Cervinka, A. S. Petronio, A. J. Nordmann, P. Diem, B. Meier, M. Zwahlen, S. Reichenbach, S. Trelle, S. Windecker, and P. Jueni. Outcomes associated with drug-eluting and bare-metal stents: a collaborative network meta-analysis. Lancet 370(9591):937–948, 2007.
Sun, F., J. Uson, J. Ezquerra, V. Crisostomo, L. Luis, and M. Maynar. Endotracheal stenting therapy in dogs with tracheal collapse. Vet. J. 175:186–193, 2008.
Tanabe, Y. Expandable metallic stent placement in the tracheobronchial tree in dogs. Radiat. Med. 11(6):224–230, 1993.
Tsakayannis, D. E., A. M. Siddiqui, H. Kozakewich, K. K. Nobuhara, J. C. Ibla, S. D. Perry, and C. W. Lillehei. The use of expandable metallic stents for acute tracheal stenosis in the growing lamb. Pediatr. Surg. 33(7):1038–1041, 1998.
Vrijhof, J., A. de Bruíne, A. A. B. Lycklama, A. Nijeholt, and L. H. Koole. A polymeric mini-stent designed to facilitate the vasectomy reversal operation. a rabbit model study. Biomaterials 25:729–734, 2004.
RetroSearch is an open source project built by @garambo | Open a GitHub Issue
Search and Browse the WWW like it's 1997 | Search results from DuckDuckGo