A RetroSearch Logo

Home - News ( United States | United Kingdom | Italy | Germany ) - Football scores

Search Query:

Showing content from https://link.springer.com/article/10.1007/s10439-010-0235-8 below:

In Vitro Study of Aortic Valves Treated with Neo-Chordae Grafts: Hydrodynamics and Tensile Force Measurements

Abstract

Reparative surgery of the aortic root functional unit (ARFU) allows for a better preservation of the functionality of the native structure compared to prosthesis implantation. Post-operative results are satisfactory, whereas mid- and long-term results are challenging, for example in terms of cusps prolapse recurrence. At the Cardiothoracic Surgery Unit of the Sacco Hospital, a new surgical technique aimed at the stabilization in time of the results of standard ARFU repair operations has been applied. This technique, inspired by the mitral neo-chordae (NC) implantation, consists of implanting an e-PTFE suture thread between the prolapsed cusp and the sinotubular junction. Aim of this study was to assess the influence of NC implantation on the ARFU functioning by evaluating with an owned pulsatile in vitro apparatus the force magnitude acting on the NC and the dynamic behavior of porcine ARFUs treated according to the operating-room procedures. The maximum recorded values of the mean and peak diastolic forces were 0.064 and 0.186 N, respectively, and were linearly dependent upon the mean diastolic pressure across the valve. In addition, the measurements of the opening–closing times and valve leakage volumes, performed at pre- and post-surgeries, yielded that the valve functionality was not significantly influenced by NC implantation.

This is a preview of subscription content, log in via an institution to check access.

Access this article Subscribe and save

Springer+ Basic

€34.99 /Month

Subscribe now Buy Now

Price includes VAT (Germany)

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others Explore related subjectsDiscover the latest articles and news from researchers in related subjects, suggested using machine learning. References
  1. Boodhwani, M., L. de Kerchove, D. Glineur, A. Poncelet, J. Rubay, P. Astarci, R. Verhelst, P. Noirhomme, and G. El Khoury. Repair-oriented classification of aortic insufficiency: impact on surgical techniques and clinical outcomes. J. Thorac. Cardiovasc. Surg. 137:286–294, 2009.

    Article  PubMed  Google Scholar 

  2. Cheng, A., P. Dagum, and D. C. Miller. Aortic root dynamics and surgery: from craft to science. Philos. Trans. R. Soc. Lond. B 362:1407–1419, 2007.

    Article  Google Scholar 

  3. Conti, C. A., E. Votta, A. Della Corte, L. Del Viscovo, C. Bancone, M. Cotrufo, and A. Redaelli. Dynamic finite element analysis of the aortic root from MRI-derived parameters. Med. Eng. Phys. 32(2):212–221, 2010.

    Article  PubMed  Google Scholar 

  4. David, T. E., J. Bos, and H. Rakowski. Mitral valve repair by replacement of chordae tendineae with polytetrafluoroethylene sutures. J. Thorac. Cardiovasc. Surg. 101:495–501, 1991.

    CAS  PubMed  Google Scholar 

  5. El Khoury, G., J. L. Vanoverschelde, D. Glineur, F. Pierard, R. R. Verhelst, J. Rubay, J. C. Funken, C. Watremez, P. Astarci, V. Lacroix, A. Poncelet, and P. Noirhomme. Repair of bicuspid aortic valves in patients with aortic regurgitation. Circulation 114:I610–I616, 2006.

    Article  PubMed  Google Scholar 

  6. Erasmi, A., H. H. Sievers, M. Scharfschwerdt, T. Eckel, and M. Misfeld. In vitro hydrodynamics, cusp-bending deformation, and root distensibility for different types of aortic valve-sparing operations: remodeling, sinus prosthesis, and reimplantation. J. Thorac. Cardiovasc. Surg. 130:1044–1049, 2005.

    Article  PubMed  Google Scholar 

  7. Fattouch, K., R. Sampognaro, G. Bianco, E. Navarra, M. Moscarelli, G. Speziale, and G. Ruvolo. Implantation of Gore-Tex chordae on aortic valve leaflet to treat prolapse using “the chordae technique”: surgical aspects and clinical results. Ann. Thorac. Surg. 85:2019–2024, 2008.

    Article  PubMed  Google Scholar 

  8. He, Z., and C. Jowers. A novel method to measure mitral valve chordal tension. J. Biomech. Eng. 131:014501, 2009.

    Article  PubMed  Google Scholar 

  9. Hopkins, R. A. Aortic valve leaflet sparing and salvage surgery: evolution of techniques for aortic root reconstruction. Eur. J. Cardiothorac. Surg. 24:886–897, 2003.

    Article  PubMed  Google Scholar 

  10. Lanzarone, E., R. Vismara, and G. B. Fiore. A new pulsatile volumetric device with biomorphic valves for the in vitro study of the cardiovascular system. Artif. Organs 33(12):1048–1062, 2009.

    Article  PubMed  Google Scholar 

  11. Lomholt, M., S. L. Nielsen, S. B. Hansen, N. T. Andersen, and J. M. Hasenkam. Differential tension between secondary and primary mitral chordae in an acute in-vivo porcine model. J. Heart Valve Dis. 11:337–345, 2002.

    PubMed  Google Scholar 

  12. Nielsen, S. L., D. D. Soerensen, P. Libergren, A. P. Yoganathan, and H. Nygaard. Miniature C-shaped transducers for chordae tendineae force measurements. Ann. Biomed. Eng. 32:1050–1057, 2004.

    Article  PubMed  Google Scholar 

  13. Vismara, R., G. B. Fiore, A. Mangini, M. Contino, M. Lemma, A. Redaelli, and C. Antona. A novel approach to the in vitro hydrodynamic study of the aortic valve: mock loop development and test. ASAIO J. 56:279–284, 2010.

    PubMed  Google Scholar 

  14. Vismara, R., K. Lagana, F. Migliavacca, S. Schievano, L. Coats, A. Taylor, and P. Bonhoeffer. Experimental setup to evaluate the performance of percutaneous pulmonary valved stent in different outflow tract morphologies. Artif. Organs 33:46–53, 2009.

    Article  PubMed  Google Scholar 

  15. Yacoub, M. H., P. J. Kilner, E. J. Birks, and M. Misfeld. The aortic outflow and root: a tale of dynamism and crosstalk. Ann. Thorac. Surg. 68:S37–S43, 1999.

    Article  CAS  PubMed  Google Scholar 

Download references

Acknowledgments

This study was funded by the Fondazione per la Ricerca in Cardiochirurgia ONLUS, Milan, Italy. The authors gratefully thank Dr. Paolo D’Alesio and Emiliano Votta, PhD, for their technical supports.

Conflict of interest statement

None.

Author information Authors and Affiliations
  1. Department of Bioengineering, Politecnico di Milano, via Golgi 39, 20133, Milan, Italy

    R. Vismara, M. Cervo, A. Redaelli & G. B. Fiore

  2. FoRCardioLab, Fondazione per la Ricerca in Cardiochirurgia ONLUS, Milan, Italy

    R. Vismara, C. Antona, A. Mangini, M. Cervo, M. Contino, E. Bosisio, A. Redaelli & G. B. Fiore

  3. Cardiac Surgery Unit, H.L. Sacco, Università di Milano, Milan, Italy

    C. Antona, A. Mangini, M. Contino & E. Bosisio

Authors
  1. R. Vismara
  2. C. Antona
  3. A. Mangini
  4. M. Cervo
  5. M. Contino
  6. E. Bosisio
  7. A. Redaelli
  8. G. B. Fiore
Corresponding author

Correspondence to R. Vismara.

Additional information

Associate Editor Stefan Jockenhoevel oversaw the review of this article.

About this article Cite this article

Vismara, R., Antona, C., Mangini, A. et al. In Vitro Study of Aortic Valves Treated with Neo-Chordae Grafts: Hydrodynamics and Tensile Force Measurements. Ann Biomed Eng 39, 1024–1031 (2011). https://doi.org/10.1007/s10439-010-0235-8

Download citation

Keywords

RetroSearch is an open source project built by @garambo | Open a GitHub Issue

Search and Browse the WWW like it's 1997 | Search results from DuckDuckGo

HTML: 3.2 | Encoding: UTF-8 | Version: 0.7.4