Bassiouny H. S., S. White, S. Glagov, E. Choi, D. P. Giddens, C. K. Zarins 1992 Anastomotic intimal hyperplasia: mechanical injury or flow induced. J. Vasc. Surg. 15, 708–717. doi:10.1067/mva.1992.33849
Brumby S. A., M. F. Petrucco, J. A. Walsh, M. J. Bond 1992 A retrospective analysis of infra-inguinal arterial reconstruction: three-year patency rates. Aust. New Zeal. J. Surg. 62, 256–260. doi:10.1111/j.1445-2197.1992.tb07551.x
Clowes A. W., M. M. Clowes, J. Fingerle, M. A. Reidy 1989 Kinetics of cellular proliferation after arterial injury. Role of acute distension in the induction of smooth muscle proliferation. Lab. Invest. 60, 360–364
Cole J. S., J. K. Watterson, M. J. G. O’Reilly 2002 Is there a haemodynamic advantage associated with cuffed arterial anatomoses? J. Biomech. 35, 1337–1346. doi:10.1016/S0021-9290(02)00174-4
Da Silva A., T. Carpenter, T. V. How, P. L. Harris 1997 Stable vortices within vein cuffs inhibit anastomotic myointimal hyperplasia? Eur. J. Vasc. Endovasc. 14, 157–163. doi:10.1016/S1078-5884(97)80185-2
Dobrin P. B., F. N. Littooy, E. D. Endean 1989 Mechanical factors predisposing to intimal hyperplasia and medial thickening in autogenous vein grafts. Surgery 105, 393–400
Fisher R. K, T. V. How, T. Carpenter, J. A. Brennan, P. L. Harris 2001 Optimising Miller cuff dimensions. The influence of geometry on anastomotic flow patterns. Eur. J. Vasc. Endovasc. 21, 251–260. doi:10.1053/ejvs.2000.1273
Friedman M. H., C. B. Bargeron, D. D. Duncan, G. K. Hutchins, F. F. Mark 1992 Effects of arterial compliance and non-newtonian rheology on correlations between intimal thickness and wall shear. J. Biomech. Eng. 114, 317–320. doi:10.1115/1.2891389
Harris P. L., T. V. How 1999 Haemodynamics of cuffed arterial anastomoses. Critical Ischaemia 9, 20–26
How T. V., R. K. Fisher, J. A. Brennan, P. L. Harris 2006 Swirling flow pattern in a non-planar model of an interposition vein cuff anastomosis. Med. Eng. Phys. 28, 27–35. doi:10.1016/j.medengphy.2005.04.016
How T. V., C. S. Rowe, G. L. Gilling-Smith, P. L. Harris 2000 Interposition vein cuff anastomosis alters wall shear stress distribution in the recipient artery. J. Vasc. Surg. 31, 1008–1017. doi:10.1067/mva.2000.105961
Keynton R. S., M. M. Evancho, R. L. Sims, N. V. Rodway, A. Gobin, S. E. Rittgers 2001 Intimal hyperplasia and wall shear in arterial bypass graft distal anastomoses: an in vivo model study. ASME J. Biomech Eng. 123, 464–473. doi:10.1115/1.1389461
Kissin M., N. Kansal, P. J. Pappas, D. O. DeFouw, W. N. Durán, R. W. Hobson 2000 Vein interposition cuffs decrease the intimal hyperplasia response of polytetrafluoroethylene bypass grafts. J. Vasc. Surg. 31(1), 69–83. doi:10.1016/S0741-5214(00)70069-3
Kraiss L. W., A. W. Clowes 1997 Responses of the arterial wall to injury and intimal hyperplasia. In: A. N. Sidawy, B. E. Sumpio, R. G. DePalma (eds) The Basic Science of Vascular Disease. Armonk NY: Future Publishing Company Inc., pp. 289–317
Kraiss L. W., R. L. Geary, E. J. R. Mattsson, S. Vergel, Y. P. T. Au, A. W. Clowes 1996 Acute reductions in blood flow and shear stress induce PDGF-A expression in balloon prosthetic grafts. Circ. Res. 79, 45–53
Ku D. N., D. P. Giddens, C. K. Zarins, S. Glagov 1985 Pulsatile flow and atherosclerosis in the human carotid bifurcation—positive correlation between plaque location and oscillating shear stress. Arteriosclerosis 5, 292–302
Lemson M. S., J. H. M. Tordoir, M. J. A. P. Daemen, P. J. E. H. M. Kitslaar 2000 Intimal Hyperplasia in Vascular Grafts. Eur. J. Vasc. Endovasc. 19, 336–350. doi:10.1053/ejvs.1999.1040
Meyerson S. L., C. L. Skelly, M. A. Curi 2001 The effects of extremely low shear stress on cellular proliferation and neointimal thickening in the failing bypass graft. J. Vasc. Surg. 34, 90–97. doi:10.1067/mva.2001.114819
Miller J. H., R. K. Foreman, L. Ferguson, I. Faris 1984 Interposition vein cuff for anastomosis of prosthesis to small artery. Aust. New Zeal. J. Surg. 54, 283–285. doi:10.1111/j.1445-2197.1984.tb05318.x
Moore J. A., D. A. Steinman, S. Prakash, K. W. Johnston, C. R. Ethier 1999 A numerical study of blood flow patterns in anatomically realistic and simplified end-to-side anastomoses. ASME J. Biomech. Eng. 121, 265–272. doi:10.1115/1.2798319
Morris G. E., S. Raptis, J. H. Miller, I. B. Faris 1993 Femorocrural grafting and regrafting: does polytetrafluoroethylene have a role? Eur. J. Vasc. Endovasc. 7, 329–334
Norberto J. J., A. N. Sidawy, K. S. Trad, B. A. Jones, R. F. Neville, S. F. Najjar, M. K. Sidawy, R. G. DePalma 1995 The protective effect of vein cuffed anastomoses is not mechanical in origin. J. Vasc. Surg. 21, 558–566. doi:10.1016/S0741-5214(95)70187-7
Oderich G. S., J. M. Panneton, M. Yagubyan, T. C. Bower, J. Hofer, A. A. Noel, T. Sullivan, M. Kalra, K. J. Cherry, P. Gloviczki 2005 Comparison of precuffed and vein-cuffed expanded polytetrafluoroethylene grafts for infragenicular arterial reconstructions: a case-matched study. Ann. Vasc. Surg. 19, 49–55. doi:10.1007/s10016-004-0152-0
Ombrellaro M. P., S. L. Stevens, J. Sciarrotta, M. B. Freeman, M. H. Goldman 1996 Effect of endoluminal PTFE graft placement on cell proliferation, PDGF secretion, and intimal hyperplasia. J. Surg. Res. 63, 110–114. doi:10.1006/jsre.1996.0232
Panneton, J. M., L. M. Hollier, J. M. Hofer, and the Distaflo Trial Investigators. Multicenter randomized prospective trial comparing a pre-cuffed PTFE graft and a vein cuffed PTFE graft for infragenicular arterial bypass. Ann. Vasc. Surg. 18:199–206, 2004. doi:10.1007/s10016-004-0012-y
Papaharilaou Y., D. J. Doorly, S. J. Sherwin 2002 The influence of out-of-plane geometry on pulsatile flow within a distal end-to-side anastomosis. J. Biomech. 35, 1225–1239. doi:10.1016/S0021-9290(02)00072-6
Piorko D., P. Knez, K. Nelson, T. Schmitz-Rixen 2001 Compliance in anastomoses with and without vein cuff interposition. Eur. J. Vasc. Endovasc. 21, 461–466. doi:10.1053/ejvs.2001.1353
Steinman D. A., C. R. Ethier, X. Zhang, S. R. Karpik 1994 Effects of local geometry on anastomotic flow patterns. In: M. J. Askew (ed) Advances in Bioengineering. New York: ASME-BED, pp. 433–434
Stonebridge P. A, R. Howlett, R. Prescott, C. V. Ruchley 1995 Randomized trial comparing polytetrafluoroethylene graft patency with and without a Miller cuff. Br. J. Surg. 82, 555–556. doi:10.1002/bjs.1800820121
Suggs W. D., H. F. Henriques, R. G. DePalma 1988 Vein cuff interposition prevents juxta-anastomotic neointimal hyperplasia. Ann. Surg. 207, 717–723. doi:10.1097/00000658-198806000-00011
Trubel W., H. Schima, M. Czerny, K. Perktold, M. G. Schimek, P. Polterauer 2004 Experimental comparison of four methods of end-to-side anastomosis with expanded polytetrafluoroethylene. Brit. J. Surg. 91, 159–167. doi:10.1002/bjs.4388
Trubel W., H. Schima, A. Moritz, F. Raderer, A. Windisch, R. Ullrich 1995 Compliance mismatch and formation of distal anastomotic intimal hyperplasia in externally stiffened and lumen-adapted venous grafts. Eur. J. Vasc. Endovasc. 10, 415–423. doi:10.1016/S1078-5884(05)80163-7
Tyrrell M. R., J. H. N. Wolfe 1991 New prosthetic venous collar anastomotic technique: combining the best of other procedures. Brit. J. Surg. 78, 1016–1017. doi:10.1002/bjs.1800780840
Tyrrell M. R., J. H. N. Wolfe 1997 Myointimal hyperplasia in vein collars for ePTFE grafts. Eur. J. Vasc. Endovasc. 14, 33–36. doi:10.1016/S1078-5884(97)80222-5
Xiong F. L., C. K. Chong 2007 PIV-validated numerical modeling of pulsatile flows in distal coronary end-to-side anastomoses. J. Biomech. 40, 2872–2881. doi:10.1016/j.jbiomech.2007.03.016
Xiong F. L., C. K. Chong 2008 A parametric numerical investigation on haeodynamics in distal coronary anatomoses. Med. Eng. Phys. 30(3), 311–320. doi:10.1016/j.medengphy.2007.04.013
RetroSearch is an open source project built by @garambo | Open a GitHub Issue
Search and Browse the WWW like it's 1997 | Search results from DuckDuckGo
HTML:
3.2
| Encoding:
UTF-8
| Version:
0.7.4