You are viewing documentation for version 2 of the AWS SDK for Ruby. Version 3 documentation can be found here.
Class: Aws::CloudWatch::Alarm Instance Attribute Summary collapseIndicates whether actions should be executed during any changes to the alarm state.
The actions to execute when this alarm transitions to the ALARM
state from any other state.
The Amazon Resource Name (ARN) of the alarm.
The time stamp of the last update to the alarm configuration.
The description of the alarm.
The name of the alarm.
The arithmetic operation to use when comparing the specified statistic and threshold.
The number of data points that must be breaching to trigger the alarm.
The dimensions for the metric associated with the alarm.
Used only for alarms based on percentiles.
The number of periods over which data is compared to the specified threshold.
The percentile statistic for the metric associated with the alarm.
The actions to execute when this alarm transitions to the INSUFFICIENT_DATA
state from any other state.
The name of the metric associated with the alarm, if this is an alarm based on a single metric.
An array of MetricDataQuery structures, used in an alarm based on a metric math expression.
The namespace of the metric associated with the alarm.
The actions to execute when this alarm transitions to the OK
state from any other state.
The period, in seconds, over which the statistic is applied.
An explanation for the alarm state, in text format.
An explanation for the alarm state, in JSON format.
The time stamp of the last update to the alarm state.
The state value for the alarm.
The statistic for the metric associated with the alarm, other than percentile.
The value to compare with the specified statistic.
In an alarm based on an anomaly detection model, this is the ID of the ANOMALY_DETECTION_BAND
function used as the threshold for the alarm.
Sets how this alarm is to handle missing data points.
The unit of the metric associated with the alarm.
Deletes the specified alarms.
Retrieves the history for the specified alarm.
Disables the actions for the specified alarms.
Enables the actions for the specified alarms.
.
Returns true
if this Alarm exists.
Temporarily sets the state of an alarm for testing purposes.
Waits until this Alarm is exists.
add_data_attribute, add_identifier, #data, data_attributes, #data_loaded?, identifiers, #load, #wait_until
Methods included from Resources::OperationMethods#add_batch_operation, #add_operation, #batch_operation, #batch_operation_names, #batch_operations, #operation, #operation_names, #operations
Constructor Details #initialize(name, options = {}) ⇒ Object #initialize(options = {}) ⇒ Object Instance Attribute Details #actions_enabled ⇒ BooleanIndicates whether actions should be executed during any changes to the alarm state.
#alarm_actions ⇒ Array<String>The actions to execute when this alarm transitions to the ALARM
state from any other state. Each action is specified as an Amazon Resource Name (ARN).
The Amazon Resource Name (ARN) of the alarm.
#alarm_configuration_updated_timestamp ⇒ TimeThe time stamp of the last update to the alarm configuration.
#alarm_description ⇒ StringThe description of the alarm.
#comparison_operator ⇒ StringThe arithmetic operation to use when comparing the specified statistic and threshold. The specified statistic value is used as the first operand.
Possible values:
The number of data points that must be breaching to trigger the alarm.
#dimensions ⇒ Array<Types::Dimension>The dimensions for the metric associated with the alarm.
#evaluate_low_sample_count_percentile ⇒ StringUsed only for alarms based on percentiles. If ignore
, the alarm state does not change during periods with too few data points to be statistically significant. If evaluate
or this parameter is not used, the alarm is always evaluated and possibly changes state no matter how many data points are available.
The number of periods over which data is compared to the specified threshold.
#extended_statistic ⇒ StringThe percentile statistic for the metric associated with the alarm. Specify a value between p0.0 and p100.
#insufficient_data_actions ⇒ Array<String>The actions to execute when this alarm transitions to the INSUFFICIENT_DATA
state from any other state. Each action is specified as an Amazon Resource Name (ARN).
The name of the metric associated with the alarm, if this is an alarm based on a single metric.
#metrics ⇒ Array<Types::MetricDataQuery>An array of MetricDataQuery structures, used in an alarm based on a metric math expression. Each structure either retrieves a metric or performs a math expression. One item in the Metrics array is the math expression that the alarm watches. This expression by designated by having ReturnData
set to true.
The namespace of the metric associated with the alarm.
#ok_actions ⇒ Array<String>The actions to execute when this alarm transitions to the OK
state from any other state. Each action is specified as an Amazon Resource Name (ARN).
The period, in seconds, over which the statistic is applied.
#state_reason ⇒ StringAn explanation for the alarm state, in text format.
#state_reason_data ⇒ StringAn explanation for the alarm state, in JSON format.
#state_updated_timestamp ⇒ TimeThe time stamp of the last update to the alarm state.
#state_value ⇒ StringThe state value for the alarm.
Possible values:
The statistic for the metric associated with the alarm, other than percentile. For percentile statistics, use ExtendedStatistic
.
Possible values:
The value to compare with the specified statistic.
#threshold_metric_id ⇒ StringIn an alarm based on an anomaly detection model, this is the ID of the ANOMALY_DETECTION_BAND
function used as the threshold for the alarm.
Sets how this alarm is to handle missing data points. If this parameter is omitted, the default behavior of missing
is used.
The unit of the metric associated with the alarm.
Possible values:
Deletes the specified alarms. You can delete up to 100 alarms in one operation. However, this total can include no more than one composite alarm. For example, you could delete 99 metric alarms and one composite alarms with one operation, but you can't delete two composite alarms with one operation.
In the event of an error, no alarms are deleted.
It is possible to create a loop or cycle of composite alarms, where composite alarm A depends on composite alarm B, and composite alarm B also depends on composite alarm A. In this scenario, you can't delete any composite alarm that is part of the cycle because there is always still a composite alarm that depends on that alarm that you want to delete.
To get out of such a situation, you must break the cycle by changing the rule of one of the composite alarms in the cycle to remove a dependency that creates the cycle. The simplest change to make to break a cycle is to change the AlarmRule
of one of the alarms to False
.
Additionally, the evaluation of composite alarms stops if CloudWatch detects a cycle in the evaluation path.
#describe_history(options = {}) ⇒ Types::DescribeAlarmHistoryOutputRetrieves the history for the specified alarm. You can filter the results by date range or item type. If an alarm name is not specified, the histories for either all metric alarms or all composite alarms are returned.
CloudWatch retains the history of an alarm even if you delete the alarm.
#disable_actions ⇒ StructDisables the actions for the specified alarms. When an alarm's actions are disabled, the alarm actions do not execute when the alarm state changes.
#enable_actions ⇒ StructEnables the actions for the specified alarms.
#exists? ⇒ BooleanReturns true
if this Alarm exists. Returns false
otherwise.
Temporarily sets the state of an alarm for testing purposes. When the updated state differs from the previous value, the action configured for the appropriate state is invoked. For example, if your alarm is configured to send an Amazon SNS message when an alarm is triggered, temporarily changing the alarm state to ALARM
sends an SNS message.
Metric alarms returns to their actual state quickly, often within seconds. Because the metric alarm state change happens quickly, it is typically only visible in the alarm's History tab in the Amazon CloudWatch console or through DescribeAlarmHistory.
If you use SetAlarmState
on a composite alarm, the composite alarm is not guaranteed to return to its actual state. It returns to its actual state only once any of its children alarms change state. It is also reevaluated if you update its configuration.
If an alarm triggers EC2 Auto Scaling policies or application Auto Scaling policies, you must include information in the StateReasonData
parameter to enable the policy to take the correct action.
Waits until this Alarm is exists. This method waits by polling Client#describe_alarms until successful. An error is raised after a configurable number of failed checks.
This waiter uses the following defaults:
Configuration Default#delay
5 #max_attempts
40
You can modify defaults and register callbacks by passing a block argument.