This document shows you how to convert Application Load Balancer resources and backends from IPv4 only (single-stack) to IPv4 and IPv6 (dual-stack). The main advantage of using IPv6 is that a much larger pool of IP addresses can be allocated. You can configure the load balancer to terminate ingress IPv6 traffic and send this traffic over an IPv4 or IPv6 connection to your backends, based on your preference. For more information, see IPv6 for Application Load Balancers and proxy Network Load Balancers.
In this document, IPv4 only (single-stack) refers to the resources that use only IPv4 addresses, and IPv4 and IPv6 (dual-stack) refers to the resources that use both IPv4 and IPv6 addresses.
Before you beginNote the following conditions before you begin the conversion process:
You must be using one of the following types of Application Load Balancers:
Classic Application Load Balancers don't support dual-stack backends or subnets. For more information about IPv6 support, see IPv6 for Application Load Balancers and proxy Network Load Balancers.
Your load balancer must have either VM instance group backends or zonal network endpoint group (NEG) backends with GCE_VM_IP_PORT
endpoints. Other backend types don't have dual-stack support.
Additonally, the conversion process differs based on the type of load balancer.
For global external Application Load Balancers, you convert the backends to dual-stack and you create an IPv6 forwarding rule that can handle incoming IPv6 traffic.
For cross-region internal Application Load Balancers, regional external Application Load Balancers, and regional internal Application Load Balancers, you only convert the backends to dual-stack. IPv6 forwarding rules are not supported for these load balancers.
For information about how to set up Application Load Balancers, see the following documentation:
Note the names of the resources that your load balancer is associated with. You'll need to provide these names later.
To list all the subnets, use the gcloud compute networks subnets list
command:
gcloud compute networks subnets list
Note the name of the subnet with IPv4 only addresses to convert to dual-stack. This name is referred to later as SUBNET
. The VPC network is referred to later as NETWORK
.
To list all the backend services, use the gcloud compute backend-services list
command:
gcloud compute backend-services list
Note the name of the backend service to convert to dual-stack. This name is referred to later as BACKEND_SERVICE
.
To list all the URL maps, use the gcloud compute url-maps list
command:
gcloud compute url-maps list
Note the name of the URL map associated with your load balancer. This name is referred to later as URL_MAP
.
If you already have a load balancer, to view the IP stack type of your backends, use the gcloud compute instances list
command:
gcloud compute instances list \ --format= \ "table( name, zone.basename(), networkInterfaces[].stackType.notnull().list(), networkInterfaces[].ipv6AccessConfigs[0].externalIpv6.notnull().list():label=EXTERNAL_IPV6, networkInterfaces[].ipv6Address.notnull().list():label=INTERNAL_IPV6)"
To list all the VM instances and instance templates, use the gcloud compute instances list
command and the gcloud compute instance-templates list
command:
gcloud compute instances list
gcloud compute instance-templates list
Note the names of the instances and instance templates to convert to dual-stack. This name is referred to later as VM_INSTANCE
and INSTANCE_TEMPLATES
.
To list all the instance groups, use the gcloud compute instance-groups list
command:
gcloud compute instance-groups list
Note the name of the network endpoint groups to convert to dual stack. This name is referred to later as INSTANCE_GROUP
.
To list all the zonal network endpoint groups (NEGs), use the gcloud compute network-endpoint-groups list
command:
gcloud compute network-endpoint-groups list
Note the names of the zonal NEG backends to convert to dual-stack. This name is referred to later as ZONAL_NEG
.
To list all the target proxies, use the gcloud compute target-http-proxies list
command:
gcloud compute target-http-proxies list
Note the name of the target proxy associated with your load balancer. This name is referred to later as TARGET_PROXY
.
This section shows you how to convert your load balancer resources and backends using IPv4 only (single-stack) addresses to IPv4 and IPv6 (dual-stack) addresses.
Update the subnetDual-stack subnets are supported on custom mode VPC networks only. Dual-stack subnets are not supported on auto mode VPC networks or legacy networks. Though auto mode networks can be useful for early exploration, custom mode VPCs are better suited for most production environments. We recommend that you use VPCs in custom mode.
To update the VPC to the dual-stack setting, follow these steps:
If you are using an auto mode VPC network, you must first convert the auto mode VPC network to custom mode.
If you are using the default
network, you must convert it to a custom mode VPC network.
To enable IPv6, see Change a subnet's stack type to dual stack.
Make sure that the IPv6 access type of the subnet is set to External
.
Optional: If you want to configure internal IPv6 address ranges on subnets in this network, complete these steps:
For Allocate internal IPv6 range, select Automatically or Manually.
If you select Manually, enter a /48
range from within the fd20::/20
range. If the range is in use, you are prompted to provide a different range.
If you are using an Envoy based load balancer, we recommend that you change the proxy-only subnet stack type to dual stack. For information about load balancers that support proxy-only subnets, see Supported load balancers.
Note: Before you update the stack type of a proxy-only subnet to dual-stack, you need to assign an internal IPv6 range on the VPC network.You can't update the stack type of a proxy-only subnet (purpose=REGIONAL_MANAGED_PROXY
) in the same way that you would for a regular subnet (with the subnets update command
). Instead, you must create a backup proxy-only subnet with a dual-stack stack type and then promote it to the active role. This is because only one proxy-only subnet can be active per region, per VPC network.
After assigning an internal IPv6 range on the VPC network, do the following to change the proxy-only subnet's stack type to dual stack.
ConsoleCreate a backup proxy-only subnet in the same region as the active proxy-only subnet, specifying the IP stack type as dual-stack.
Create or modify ingress allow firewall rules that apply to your backend VMs or endpoints so that they include the primary IP address range of the backup proxy-only subnet.
Promote the backup proxy-only subnet to the active role. This action also demotes the previously active proxy-only subnet to the backup role:
After the connection draining timeout, or after you're confident that connections to your backend VMs or endpoints aren't coming from proxies in the previously active (now backup) proxy-only subnet, you can do the following:
The following steps assume you already have an existing active proxy-only subnet.
Create a backup proxy-only subnet in the same region, specifying a stack type of dual-stack (--stack-type=IPV4_IPV6
), using the gcloud compute networks subnets create command. This subnet is assigned as a backup with the --role=BACKUP
flag.
gcloud compute networks subnets create BACKUP_PROXY_ONLY_SUBNET_NAME \ --purpose=REGIONAL_MANAGED_PROXY \ --role=BACKUP \ --region=REGION \ --network=VPC_NETWORK_NAME \ --range=BACKUP_PROXY_ONLY_SUBNET_RANGE \ --stack-type=IPV4_IPV6
Replace the following:
BACKUP_PROXY_ONLY_SUBNET_NAME
: the name of the newly created backup proxy-only subnetREGION
: the region of the newly created backup proxy-only subnet. This should be the same region as the current active proxy-only subnet.VPC_NETWORK_NAME
: the network of the newly created backup proxy-only subnet. This should be the same network as the current active proxy-only subnet.VPC_NETWORK_NAME
: the name of the VPC networkBACKUP_PROXY_ONLY_SUBNET_RANGE
: the CIDR range of the newly created backup proxy-only subnetCreate or modify ingress allow firewall rules that apply to your backend VMs or endpoints so that they now include the primary IP address range of the backup proxy-only subnet. The firewall rule should already be accepting connections from the active subnet.
gcloud compute firewall-rules update PROXY_ONLY_SUBNET_FIREWALL_RULE \ --source-ranges ACTIVE_PROXY_ONLY_SUBNET_RANGE,BACKUP_PROXY_ONLY_SUBNET_RANGE
Replace the following:
PROXY_ONLY_SUBNET_FIREWALL_RULE
: the name of the firewall rule that allows traffic from the proxy-only subnet to reach your backend instances or endpointsACTIVE_PROXY_ONLY_SUBNET_RANGE
: the CIDR range of the current active proxy-only subnetBACKUP_PROXY_ONLY_SUBNET_RANGE
: the CIDR range of the backup proxy-only subnetUpdate the new subnet, setting it to be the ACTIVE
proxy-only subnet in the region and wait for the old subnet to drain. This also demotes the previously active proxy-only subnet to the backup role.
To drain an IP address range immediately, set the --drain-timeout
to 0s
. This promptly ends all connections to proxies that have assigned addresses in the subnet that is being drained.
gcloud compute networks subnets update BACKUP_PROXY_ONLY_SUBNET_NAME \ --region=REGION \ --role=ACTIVE \ --drain-timeout=CONNECTION_DRAINING_TIMEOUT
Replace the following:
BACKUP_PROXY_ONLY_SUBNET_NAME
: the name of the newly created backup proxy-only subnetREGION
: the region of the newly created backup proxy-only subnet. This should be the same region as the current active proxy-only subnet.CONNECTION_DRAINING_TIMEOUT
: the amount of time, in seconds, that Google Cloud uses to migrate existing connections away from proxies in the previously active proxy-only subnet.Monitor the status of the drain by using a list
or describe
command. The status of the subnet is DRAINING
while it is being drained.
gcloud compute networks subnets list
Wait for draining to complete. When the old proxy-only subnet is drained, the status of the subnet is READY
.
Update your proxy only subnet firewall rule to only allow connections from the new subnet.
gcloud compute firewall-rules PROXY_ONLY_SUBNET_FIREWALL_RULE \ --source-ranges BACKUP_PROXY_ONLY_SUBNET_RANGE
After you're confident that connections to your backend VMs or endpoints aren't coming from proxies in the previously active (now backup) proxy-only subnet, you can delete the old subnet.
gcloud compute networks subnets delete ACTIVE_PROXY_ONLY_SUBNET_NAME \ --region=REGION
You can configure IPv6 addresses on a VM instance if the subnet that the VM is connected to has an IPv6 range configured. Only the following backends can support IPv6 addresses:
GCE_VM_IP_PORT
type zonal NEGs.You cannot edit VM instances that are part of a managed or an unmanaged instance group. To update the VM instances to dual stack, follow these steps:
You can't update an existing instance template. If you need to make changes, you can create another template with similar properties. To update the VM instance templates to dual stack, follow these steps:
ConsoleIn the Google Cloud console, go to the Instance templates page.
allow-health-check-ipv6
.SUBNET
. Starting a basic rolling update on the managed instance group MIG
associated with the load balancer.
Zonal NEG endpoints cannot be edited. You must delete the IPv4 endpoints and create a new dual-stack endpoint with both IPv4 and IPv6 addresses.
To set up a zonal NEG (with GCE_VM_IP_PORT
type endpoints) in the REGION_A
region, first create the VMs in the GCP_NEG_ZONE
zone. Then add the VM network endpoints to the zonal NEG.
In the Google Cloud console, go to the VM instances page.
Click Create instance.
Set the Name to vm-a1
.
For the Region, choose REGION_A
, and choose any value for the Zone field. This zone is referred to as GCP_NEG_ZONE
in this procedure.
In the Boot disk section, ensure that Debian GNU/Linux 12 (bookworm) is selected for the boot disk options. Click Choose to change the image if necessary.
Expand the Advanced options section and make the following changes:
allow-health-check
.NETWORK
SUBNET
Click Management. In the Startup script field, copy and paste the following script contents.
#! /bin/bash apt-get update apt-get install apache2 -y a2ensite default-ssl a2enmod ssl vm_hostname="$(curl -H "Metadata-Flavor:Google" \ http://metadata.google.internal/computeMetadata/v1/instance/name)" echo "Page served from: $vm_hostname" | \ tee /var/www/html/index.html systemctl restart apache2
Click Create.
Repeat the following steps to create a second VM, using the following name and zone combination:
vm-a2
, zone: GCP_NEG_ZONE
Create the VMs by running the following command two times, using these combinations for the name of the VM and its zone. The script contents are identical for both VMs.
VM_NAME
of vm-a1
and any GCP_NEG_ZONE
zone of your choice.VM_NAME
of vm-a2
and the same GCP_NEG_ZONE
zone.
gcloud compute instances create VM_NAME \ --zone=GCP_NEG_ZONE \ --stack-type=IPV4_IPV6 \ --image-family=debian-12 \ --image-project=debian-cloud \ --tags=allow-health-check \ --subnet=SUBNET \ --metadata=startup-script='#! /bin/bash apt-get update apt-get install apache2 -y a2ensite default-ssl a2enmod ssl vm_hostname="$(curl -H "Metadata-Flavor:Google" \ http://metadata.google.internal/computeMetadata/v1/instance/name)" echo "Page served from: $vm_hostname" | \ tee /var/www/html/index.html systemctl restart apache2'
To add endpoints to the zonal NEG:
In the Google Cloud console, go to the Network endpoint groups page.
In the Name list, click the name of the network endpoint group (ZONAL_NEG
). You see the Network endpoint group details page.
In the Network endpoints in this group section, select the previously created NEG endpoint. Click Remove endpoint.
In the Network endpoints in this group section, click Add network endpoint.
Select the VM instance.
In the Network interface section, the name, zone, and subnet of the VM is displayed.
In the IPv4 address field, enter the IPv4 address of the new network endpoint.
In the IPv6 address field, enter the IPv6 address of the new network endpoint.
Note: A backend service with multiple endpoints must have unique IPv6 addresses. The endpoints can be in different subnets, but the same IPv6 address cannot be used for multiple endpoints.Select the Port type.
80
for all endpoints in the network endpoint group. This is sufficient for our example because the Apache server is serving requests at port 80
.To add more endpoints, click Add network endpoint and repeat the previous steps.
After you add all the endpoints, click Create.
Add endpoints (GCE_VM_IP_PORT
endpoints) to ZONAL_NEG
.
gcloud compute network-endpoint-groups update ZONAL_NEG \ --zone=GCP_NEG_ZONE \ --add-endpoint='instance=vm-a1,ip=IPv4_ADDRESS, \ ipv6=IPv6_ADDRESS,port=80' \ --add-endpoint='instance=vm-a2,ip=IPv4_ADDRESS, \ ipv6=IPv6_ADDRESS,port=80'
Replace the following:
IPv4_ADDRESS
: IPv4 address of the network endpoint. The IPv4 must belong to a VM in Compute Engine (either the primary IP or as part of an aliased IP range). If the IP address is not specified, then the primary IP address for the VM instance in the network that the network endpoint group belongs to is used.
IPv6_ADDRESS
: IPv6 address of the network endpoint. The IPv6 address must belong to a VM instance in the network that the network endpoint group belongs (external IPv6 address).
You must create a firewall rule to allow health checks from the IP ranges of Google Cloud probe systems. For more information, see probe IP ranges.
Ensure that the ingress rule is applicable to the instances being load balanced and that it allows traffic from the Google Cloud health checking systems. This example uses the target tag allow-health-check-ipv6
to identify the VM instances to which it applies.
Without this firewall rule, the default deny ingress rule blocks incoming IPv6 traffic to the backend instances.
ConsoleIn the Google Cloud console, go to the Firewall policies page.
To allow IPv6 subnet traffic, click Create firewall rule again and enter the following information:
fw-allow-lb-access-ipv6
NETWORK
1000
allow-health-check-ipv6
Source IPv6 ranges:
For global external Application Load Balancer and global external proxy Network Load Balancer, enter 2600:2d00:1:b029::/64
,2600:2d00:1:1::/64
For cross-region internal Application Load Balancer, regional external Application Load Balancer, regional internal Application Load Balancer, cross-region internal proxy Network Load Balancer, regional external proxy Network Load Balancer, and regional internal proxy Network Load Balancer, enter 2600:2d00:1:b029::/64
Protocols and ports: Allow all
Click Create.
Create the fw-allow-lb-access-ipv6
firewall rule to allow communication with the subnet.
For global external Application Load Balancer and global external proxy Network Load Balancer, use the following command:
gcloud compute firewall-rules create fw-allow-lb-access-ipv6 \ --network=NETWORK \ --action=allow \ --direction=ingress \ --target-tags=allow-health-check-ipv6 \ --source-ranges=2600:2d00:1:b029::/64,2600:2d00:1:1::/64 \ --rules=all
For cross-region internal Application Load Balancer, regional external Application Load Balancer, regional internal Application Load Balancer, cross-region internal proxy Network Load Balancer, regional external proxy Network Load Balancer, and regional internal proxy Network Load Balancer, use the following command:
gcloud compute firewall-rules create fw-allow-lb-access-ipv6 \ --network=NETWORK \ --action=allow \ --direction=ingress \ --target-tags=allow-health-check-ipv6 \ --source-ranges=2600:2d00:1:b029::/64 \ --rules=all
If you are using a regional external Application Load Balancer or an internal Application Load Balancer, you must update the ingress firewall rule
fw-allow-lb-access-ipv6
to allow traffic from the proxy-only subnet to the backends.
To get the IPv6 address range of the proxy-only subnet, run the following command:
gcloud compute networks subnets describe PROXY_ONLY_SUBNET \ --region=REGION \ --format="value(internalIpv6Prefix)"
Note the internal IPv6 address range; this range is later referred to as IPV6_PROXY_ONLY_SUBNET_RANGE
.
To update the firewall rule fw-allow-lb-access-ipv6
for proxy-only subnet, do the following:
In the Google Cloud console, go to the Firewall policies page.
In the VPC firewall rules panel, click fw-allow-lb-access-ipv6
.
2600:2d00:1:b029::/64
, IPV6_PROXY_ONLY_SUBNET_RANGEClick Save.
Update the fw-allow-lb-access-ipv6
firewall rule to allow communication with the proxy-only subnet:
gcloud compute firewall-rules update fw-allow-lb-access-ipv6 \ --source-ranges=2600:2d00:1:b029::/64,IPV6_PROXY_ONLY_SUBNET_RANGE
This section describes the procedure to create a new backend service and a forwarding rule for IPv6. Note that the IPv6 forwarding rule can be created only for global external Application Load Balancers. IPv6 forwarding rules aren't supported for cross-region internal Application Load Balancers, regional external Application Load Balancers, and regional internal Application Load Balancers.
At this point in the process, both BACKEND_SERVICE
and BACKEND_SERVICE_IPV6
are capable of serving traffic. To avoid traffic disruption, create a new backend service with the IP address selection policy set to Prefer IPv6
. After you create the new backend service, you can route traffic to the new IPv6 backend service.
In the Google Cloud console, go to the Load balancing page.
Click the name of the load balancer.
Click Edit.
10
.Forwarding rule with IPv6 is not supported for cross-region internal Application Load Balancers, regional external Application Load Balancers, and regional internal Application Load Balancers.
HTTP
.IPv6
.Create a health check:
gcloud compute health-checks create http HEALTH_CHECK \ --port 80
Create the backend service for HTTP traffic:
globalFor the global external Application Load Balancer, use the command:
gcloud compute backend-services create BACKEND_SERVICE_IPV6 \ --load-balancing-scheme=EXTERNAL_MANAGED \ --protocol=HTTP \ --ip-address-selection-policy=PREFER_IPV6 \ --health-checks=HEALTH_CHECK \ --globalcross-region
For the cross-region internal Application Load Balancer, use the command:
gcloud compute backend-services create BACKEND_SERVICE_IPV6 \ --load-balancing-scheme=INTERNAL_MANAGED \ --protocol=HTTP \ --ip-address-selection-policy=PREFER_IPV6 \ --health-checks=HEALTH_CHECK \ --globalregional
For the regional external Application Load Balancer, use the command:
gcloud compute backend-services create BACKEND_SERVICE_IPV6 \ --load-balancing-scheme=EXTERNAL_MANAGED \ --protocol=HTTP \ --ip-address-selection-policy=PREFER_IPV6 \ --health-checks=HEALTH_CHECK \ --region=REGION
For the regional internal Application Load Balancer, use the command:
gcloud compute backend-services create BACKEND_SERVICE_IPV6 \ --load-balancing-scheme=INTERNAL_MANAGED \ --protocol=HTTP \ --ip-address-selection-policy=PREFER_IPV6 \ --health-checks=HEALTH_CHECK \ --region=REGION
Add the dual-stack zonal NEGs as the backend to the backend service.
globalFor the global external Application Load Balancer, use the command:
gcloud compute backend-services add-backend BACKEND_SERVICE_IPV6 \ --network-endpoint-group=ZONAL_NEG \ --network-endpoint-group-zone=ZONE \ --max-rate-per-endpoint=10 \ --globalcross-region
For the cross-region internal Application Load Balancer, use the command:
gcloud compute backend-services add-backend BACKEND_SERVICE_IPV6 \ --network-endpoint-group=ZONAL_NEG \ --network-endpoint-group-zone=ZONE \ --max-rate-per-endpoint=10 \ --globalregional
For the regional external Application Load Balancer and the regional internal Application Load Balancer, use the command:
gcloud compute backend-services add-backend BACKEND_SERVICE_IPV6 \ --network-endpoint-group=ZONAL_NEG \ --network-endpoint-group-zone=ZONE \ --max-rate-per-endpoint=10 \ --region=REGION
Add the dual-stack instance groups as the backend to the backend service.
globalFor the global external Application Load Balancer, use the command:
gcloud compute backend-services add-backend BACKEND_SERVICE_IPV6 \ --instance-group=INSTANCE_GROUP \ --globalcross-region
For the cross-region internal Application Load Balancer, use the command:
gcloud compute backend-services add-backend BACKEND_SERVICE_IPV6 \ --instance-group=INSTANCE_GROUP \ --globalregional
For the regional external Application Load Balancer and the regional internal Application Load Balancer, use the command:
gcloud compute backend-services add-backend BACKEND_SERVICE_IPV6 \ --instance-group=INSTANCE_GROUP \ --region=REGION
For global external Application Load Balancers only. Create the IPv6 forwarding rule for the global external Application Load Balancer. Use the command:
gcloud compute forwarding-rules create FORWARDING_RULE_IPV6 \ --load-balancing-scheme=EXTERNAL_MANAGED \ --network-tier=PREMIUM \ --global \ --target-http-proxy=TARGET_PROXY \ --ports=443
Update the URL map to direct some fraction of client traffic to the new IPv6 backend service BACKEND_SERVICE_IPV6
.
Use the following command to edit the URL maps:
globalFor the global external Application Load Balancer, use the command:
gcloud compute url-maps edit URL_MAP \ --globalcross-region
For the cross-region internal Application Load Balancer, use the command:
gcloud compute url-maps edit URL_MAP \ --globalregional
For the regional external Application Load Balancer and the regional internal Application Load Balancer, use the command:
gcloud compute url-maps edit URL_MAP \ --region=REGION
In the text editor that appears, add a routeRule
with a weightedBackendServices
action that directs a percentage of IPv6 traffic to BACKEND_SERVICE_IPV6
.
defaultService: global/backendServices/BACKEND_SERVICE
hostRules:
- hosts:
- '*'
pathMatcher: matcher1
name: URL_MAP
pathMatchers:
- defaultService: global/backendServices/BACKEND_SERVICE
name: matcher1
routeRules:
- matchRules:
- prefixMatch: ''
priority: 1
routeAction:
weightedBackendServices:
- backendService: global/backendServices/BACKEND_SERVICE
weight: 95
- backendService: global/backendServices/BACKEND_SERVICE_IPV6
weight: 5
To implement gradual migration to IPv6, increase the weight percentage for the new backend service BACKEND_SERVICE_IPV6
incrementally to 100% by editing the URL map many times.
After you have converted your resources and backends to dual-stack, you can use the IP address selection policy to specify the traffic type that is sent from the backend service to your backends.
Replace IP_ADDRESS_SELECTION_POLICY
with any of the following values:
Prioritize the backend's IPv6 connection over the IPv4 connection (provided there is a healthy backend with IPv6 addresses).
The health checks periodically monitor the backends' IPv6 and IPv4 connections. The GFE first attempts the IPv6 connection; if the IPv6 connection is broken or slow, the GFE uses happy eyeballs to fall back and connect to IPv4.
Even if one of the IPv6 or IPv4 connections is unhealthy, the backend is still treated as healthy, and both connections can be tried by the GFE, with happy eyeballs ultimately selecting which one to use.
Only IPv6Only send IPv6 traffic to the backends of the backend service, regardless of traffic from the client to the proxy. Only IPv6 health checks are used to check the health of the backends.
There is no validation to check if the backend traffic type matches the IP address selection policy. For example, if you have IPv4-only backends and select Only IPv6
as the IP address selection policy, the configuration results in unhealthy backends because traffic fails to reach those backends and the HTTP 503
response code is returned to the clients.
In the Google Cloud console, go to the Load balancing page.
Click the name of the load balancer.
Click Edit.
Click Backend configuration.
In the Backend service field, select BACKEND_SERVICE_IPV6.
The Backend type must be Zonal network endpoint group or Instance group.
In the IP address selection policy list, select IP_ADDRESS_SELECTION_POLICY.
Click Done.
Update the IP address selection policy for the backend service:
globalFor the global external Application Load Balancer, use the command:
gcloud compute backend-services update BACKEND_SERVICE_IPV6 \ --load-balancing-scheme=EXTERNAL_MANAGED \ --protocol=HTTP \ --ip-address-selection-policy=IP_ADDRESS_SELECTION_POLICY \ --globalcross-region
For the cross-region internal Application Load Balancer, use the command:
gcloud compute backend-services update BACKEND_SERVICE_IPV6 \ --load-balancing-scheme=INTERNAL_MANAGED \ --protocol=HTTP \ --ip-address-selection-policy=IP_ADDRESS_SELECTION_POLICY \ --globalregional
For the regional external Application Load Balancer, use the command:
gcloud compute backend-services update BACKEND_SERVICE_IPV6 \ --load-balancing-scheme=EXTERNAL_MANAGED \ --protocol=HTTP \ --ip-address-selection-policy=IP_ADDRESS_SELECTION_POLICY \ --region=REGION
For the regional internal Application Load Balancer, use the command:
gcloud compute backend-services update BACKEND_SERVICE_IPV6 \ --load-balancing-scheme=INTERNAL_MANAGED \ --protocol=HTTP \ --ip-address-selection-policy=IP_ADDRESS_SELECTION_POLICY \ --region=REGIONTest your load balancer
You must validate that all required resources are updated to dual stack. After you update all the resources, the traffic must automatically flow to the backends. You can check the logs and verify that the conversion is complete.
Test the load balancer to confirm that the migration is successful and the incoming traffic is reaching the backends as expected.
Look up the load balancer IP addresses ConsoleIn the Google Cloud console, go to the Load balancing page.
Click the name of the load balancer.
In the Frontend section, two load balancer IP addresses are displayed. In this procedure, the IPv4 address is referred to as IP_ADDRESS_IPV4 and the IPv6 address is referred as IP_ADDRESS_IPV6.
In the Backends section, when the IP address selection policy is Prefer IPv6
two health check status are displayed for the backends.
In this example, requests from the curl
command are distributed randomly to the backends.
Repeat the following commands a few times until you see all the backend VMs responding:
curl -m1 IP_ADDRESS_IPV4:PORT
curl -m1 IP_ADDRESS_IPV6:PORT
For example, if the IPv6 address is [fd20:1db0:b882:802:0:46:0:0]:80
, the command looks similar to this:
curl -m1 [fd20:1db0:b882:802:0:46:0:0]:80
Create a test client VM in the same VPC network and region as the load balancer. It doesn't need to be in the same subnet or zone.
gcloud compute instances create client-vm \ --zone=ZONE \ --image-family=debian-12 \ --image-project=debian-cloud \ --tags=allow-ssh \ --subnet=SUBNET
Use SSH to connect to the client instance.
gcloud compute ssh client-vm \ --zone=ZONE
Repeat the following commands a few times until you see all the backend VMs responding:
curl -m1 IP_ADDRESS_IPV4:PORT
curl -m1 IP_ADDRESS_IPV6:PORT
For example, if the IPv6 address is [fd20:1db0:b882:802:0:46:0:0]:80
, the command looks similar to this:
curl -m1 [fd20:1db0:b882:802:0:46:0:0]:80
Every log entry captures the destination IPv4 and IPv6 address for the backend. Because we support dual-stack, it is important to observe the IP address used by the backend.
You can check that traffic is going to IPv6 or failing back to IPv4 by viewing the logs.
The HttpRequest contains the backend_ip
address associated with the backend. By examining the logs and comparing the destination IPv4 and IPv6 address of the backend_ip
, you can confirm which IP address is used.