Before you start, you should double check that your Windows firewall rules are set up to allow traffic from the IP address of the new Windows instance you created. Then, create a new database for TPCC load testing and configure a user account using the following steps:
Set the Autogrowth limits to higher values by clicking the ellipsis buttons, as shown in the following screenshot:
Set the data file to grow by 64 MB to unlimited size.
Set the log file to disable auto-growth.
Click OK.
In the New Database dialog, in the left pane, choose the Options page.
Set Compatibility level to SQL Server 2022 (160).
Set the Recovery model to Simple, so that the loading doesn't fill up the transaction logs.
Click OK to create the TPCC database, which can take a few minutes to complete.
The preconfigured SQL Server image comes with only Windows Authentication enabled, so you will need to enable mixed mode authentication within SSMS, by following this guide.
Follow these steps to create a new SQL Server user account on your database server that has the DBOwner permission. Name the account "loaduser" and give it a secure password.
Take note of your SQL Server internal IP address by using the Get-NetIPAddress
commandlet, because it's important for performance and security to use the internal IP.
You can run HammerDB directly on your SQL Server instance. However, for a more accurate test, create a new Windows instance and test the SQL Server instance remotely.
Note: You might need to disable Internet Explorer Enhanced Security Configuration before downloading files to your Windows Server instance. Creating an instanceFollow these steps to create a new Compute Engine instance:
In the Google Cloud console, go to the Create an instance page.
For Name, enter hammerdb-instance
.
In the Machine configuration section, select the machine type with at least half the number of CPUs as your database instance.
In the Boot disk section, click Change, and then do the following:
To create and start the VM, click Create.
When it's ready, use an RDP client to connect to your new Windows Server instance and install the following software:
Running HammerDBAfter you install HammerDB, run the hammerdb.bat
file. HammberDB does not show up in the Start menu's applications list. Use the following command to run HammerDB:
C:\Program Files\HammerDB-VERSION
\hammerdb.bat
Replace VERSION
with the version of the installed HammerDB.
When the application is running, the first step is to configure the connection to build the schema.
TPROC-C is the OLTP workload implemented in HammerDB derived from the TPROC-C specification with modification to make running HammerDB straightforward and cost-effective on any of the supported database environments. The HammerDB TPROC-C workload is an open source workload derived from the TPROC-C Benchmark Standard and as such is not comparable to published TPROC-C results, as the results comply with a subset rather than the full TPROC-C Benchmark Standard. The name for the HammerDB workload TPROC-C means "Transaction Processing Benchmark derived from the TPC "C" specification".
Click OK
Click Schema and then double-click Options.
Fill out the form using your IP address, username, and password as shown in the following image:
Set the SQL Server ODBC Driver to OBDC Driver 18 for SQL Server
In this case, the Number of Warehouses (the scale) is set to 460, but you can choose a different value. Some guidelines suggest 10 to 100 warehouses per CPU. For this tutorial, set this value to 10 times the number of cores: 160 for a 16-core instance.
For Virtual Users to Build Schema, choose a number that is between 1- and 2-times the number of client vCPUs. You can click the grey bar next to the slider to increment the number.
Clear the Use BPC Option
Click OK
Double-click the Build option below the Schema Build section to create the schema and load the tables. When that completes, click the red flash light icon in the top center of the screen to destroy the virtual user and move to the next step.
If you created your database with the Simple
recovery model, you might want to change it back to Full
at this point to get a more accurate test of a production scenario. This change doesn't take effect until after you take a full or differential backup to trigger the start of the new log chain.
HammerDB uses the driver script to orchestrate the flow of SQL statements to the database to generate the required load.
Creating a realistic load typically requires running scripts as multiple different users. Create some virtual users for the test.
HammerDB and SQL Server don't easily collect detailed runtime statistics for you. Although the statistics are available deep within SQL Server, they need to be captured and calculated on a regular basis. If you do not already have a procedure or tool to help capture this data, you can use the procedure in this section to capture some useful metrics during your testing. The results will be written to a CSV file in the Windows temp
directory. You can copy the data to a Google Sheet using the Paste Special > Paste CSV option.
To use this procedure, you first must temporarily enable OLE Automation Procedures to write the file to disk. Remember to disable it after testing:
sp_configure 'show advanced options', 1; GO RECONFIGURE; GO sp_configure 'Ole Automation Procedures', 1; GO RECONFIGURE; GONote: Although this procedure is very small, it can affect the total throughput reported by a fraction of a percent.
Here's the code to create the sp_write_performance_counters
procedure in SQL Server Management Studio. Before starting the load test, you will execute this procedure in Management Studio.:
USE [master] GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO /*** LogFile path has to be in a directory that SQL Server can Write To. */ CREATE PROCEDURE [dbo].[sp_write_performance_counters] @LogFile varchar (2000) = 'C:\\WINDOWS\\TEMP\\sqlPerf.log', @SecondsToRun int =1600, @RunIntervalSeconds int = 2 AS BEGIN --File writing variables DECLARE @OACreate INT, @OAFile INT, @FileName VARCHAR(2000), @RowText VARCHAR(500), @Loops int, @LoopCounter int, @WaitForSeconds varchar (10) --Variables to save last counter values DECLARE @LastTPS BIGINT, @LastLRS BIGINT, @LastLTS BIGINT, @LastLWS BIGINT, @LastNDS BIGINT, @LastAWT BIGINT, @LastAWT_Base BIGINT, @LastALWT BIGINT, @LastALWT_Base BIGINT --Variables to save current counter values DECLARE @TPS BIGINT, @Active BIGINT, @SCM BIGINT, @LRS BIGINT, @LTS BIGINT, @LWS BIGINT, @NDS BIGINT, @AWT BIGINT, @AWT_Base BIGINT, @ALWT BIGINT, @ALWT_Base BIGINT, @ALWT_DIV BIGINT, @AWT_DIV BIGINT SELECT @Loops = case when (@SecondsToRun % @RunIntervalSeconds) > 5 then @SecondsToRun / @RunIntervalSeconds + 1 else @SecondsToRun / @RunIntervalSeconds end SET @LoopCounter = 0 SELECT @WaitForSeconds = CONVERT(varchar, DATEADD(s, @RunIntervalSeconds , 0), 114) SELECT @FileName = @LogFile + FORMAT ( GETDATE(), '-MM-dd-yyyy_m', 'en-US' ) + '.txt' --Create the File Handler and Open the File EXECUTE sp_OACreate 'Scripting.FileSystemObject', @OACreate OUT EXECUTE sp_OAMethod @OACreate, 'OpenTextFile', @OAFile OUT, @FileName, 2, True, -2 --Write the Header EXECUTE sp_OAMethod @OAFile, 'WriteLine', NULL,'Transactions/sec, Active Transactions, SQL Cache Memory (KB), Lock Requests/sec, Lock Timeouts/sec, Lock Waits/sec, Number of Deadlocks/sec, Average Wait Time (ms), Average Latch Wait Time (ms)' --Collect Initial Sample Values SET ANSI_WARNINGS OFF SELECT @LastTPS= max(case when counter_name = 'Transactions/sec' then cntr_value end), @LastLRS = max(case when counter_name = 'Lock Requests/sec' then cntr_value end), @LastLTS = max(case when counter_name = 'Lock Timeouts/sec' then cntr_value end), @LastLWS = max(case when counter_name = 'Lock Waits/sec' then cntr_value end), @LastNDS = max(case when counter_name = 'Number of Deadlocks/sec' then cntr_value end), @LastAWT = max(case when counter_name = 'Average Wait Time (ms)' then cntr_value end), @LastAWT_Base = max(case when counter_name = 'Average Wait Time base' then cntr_value end), @LastALWT = max(case when counter_name = 'Average Latch Wait Time (ms)' then cntr_value end), @LastALWT_Base = max(case when counter_name = 'Average Latch Wait Time base' then cntr_value end) FROM sys.dm_os_performance_counters WHERE counter_name IN ( 'Transactions/sec', 'Lock Requests/sec', 'Lock Timeouts/sec', 'Lock Waits/sec', 'Number of Deadlocks/sec', 'Average Wait Time (ms)', 'Average Wait Time base', 'Average Latch Wait Time (ms)', 'Average Latch Wait Time base') AND instance_name IN( '_Total' ,'') SET ANSI_WARNINGS ON WHILE @LoopCounter <= @Loops BEGIN WAITFOR DELAY @WaitForSeconds SET ANSI_WARNINGS OFF SELECT @TPS= max(case when counter_name = 'Transactions/sec' then cntr_value end) , @Active = max(case when counter_name = 'Active Transactions' then cntr_value end) , @SCM = max(case when counter_name = 'SQL Cache Memory (KB)' then cntr_value end) , @LRS = max(case when counter_name = 'Lock Requests/sec' then cntr_value end) , @LTS = max(case when counter_name = 'Lock Timeouts/sec' then cntr_value end) , @LWS = max(case when counter_name = 'Lock Waits/sec' then cntr_value end) , @NDS = max(case when counter_name = 'Number of Deadlocks/sec' then cntr_value end) , @AWT = max(case when counter_name = 'Average Wait Time (ms)' then cntr_value end) , @AWT_Base = max(case when counter_name = 'Average Wait Time base' then cntr_value end) , @ALWT = max(case when counter_name = 'Average Latch Wait Time (ms)' then cntr_value end) , @ALWT_Base = max(case when counter_name = 'Average Latch Wait Time base' then cntr_value end) FROM sys.dm_os_performance_counters WHERE counter_name IN ( 'Transactions/sec', 'Active Transactions', 'SQL Cache Memory (KB)', 'Lock Requests/sec', 'Lock Timeouts/sec', 'Lock Waits/sec', 'Number of Deadlocks/sec', 'Average Wait Time (ms)', 'Average Wait Time base', 'Average Latch Wait Time (ms)', 'Average Latch Wait Time base') AND instance_name IN( '_Total' ,'') SET ANSI_WARNINGS ON SELECT @AWT_DIV = case when (@AWT_Base - @LastAWT_Base) > 0 then (@AWT_Base - @LastAWT_Base) else 1 end , @ALWT_DIV = case when (@ALWT_Base - @LastALWT_Base) > 0 then (@ALWT_Base - @LastALWT_Base) else 1 end SELECT @RowText = '' + convert(varchar, (@TPS - @LastTPS)/@RunIntervalSeconds) + ', ' + convert(varchar, @Active) + ', ' + convert(varchar, @SCM) + ', ' + convert(varchar, (@LRS - @LastLRS)/@RunIntervalSeconds) + ', ' + convert(varchar, (@LTS - @LastLTS)/@RunIntervalSeconds) + ', ' + convert(varchar, (@LWS - @LastLWS)/@RunIntervalSeconds) + ', ' + convert(varchar, (@NDS - @LastNDS)/@RunIntervalSeconds) + ', ' + convert(varchar, (@AWT - @LastAWT)/@AWT_DIV) + ', ' + convert(varchar, (@ALWT - @LastALWT)/@ALWT_DIV) SELECT @LastTPS = @TPS, @LastLRS = @LRS, @LastLTS = @LTS, @LastLWS = @LWS, @LastNDS = @NDS, @LastAWT = @AWT, @LastAWT_Base = @AWT_Base, @LastALWT = @ALWT, @LastALWT_Base = @ALWT_Base EXECUTE sp_OAMethod @OAFile, 'WriteLine', Null, @RowText SET @LoopCounter = @LoopCounter + 1 END --CLEAN UP EXECUTE sp_OADestroy @OAFile EXECUTE sp_OADestroy @OACreate print 'Completed Logging Performance Metrics to file: ' + @FileName END GORunning the TPROC-C load test
In SQL Server Management Studio, execute the collection procedure using the following script:
Use master Go exec dbo.sp_write_performance_counters
On the Compute Engine instance where you installed HammerDB, start the test in the HammerDB application:
c:\Windows\temp